English
Language : 

DRM-24V120W1PN Datasheet, PDF (6/20 Pages) Delta Electronics, Inc. – Universal AC input voltage range
TECHNICAL DATASHEET
CliQ M DIN Rail Power Supply
24V 120W 1 Phase / DRM-24V120W1PN
Protections
Overvoltage
Overload / Overcurrent
Over Temperature
Short Circuit
Transient Surge Voltage Protection
Internal Fuse
Degree of Protection
Protection Against Shock
*PE: Primary Earth
28.8 – 35.2V, SELV Output,
Hiccup Mode, Non-Latching
(Auto-Recovery)
Refer to the details in the Function
section
> 150% of rated load current, Refer to the details in the Function
Constant current, Hiccup
section
Mode (Auto-Recovery)
< 80°C Surrounding Air
Refer to the details in the Function
Temperature @ 100% load, section
Non-Latching (Auto-Recovery)
Hiccup Mode, Non-Latching Load impedance ≤ 100mOhm, refer to
(Auto-Recovery when the fault the details in the Function section
is removed)
MOV (Metal Oxide Varistor)
T3.15A
IP20
Class I with PE* connection
Reliability Data
MTBF (as per Telcordia SR-332)
1,831,000 hrs.
976,000 hrs.
I/P: 100Vac, O/P: 24V, 5A, Ta: 25°C
I/P: 100Vac, O/P: 24V, 5A, Ta: 40°C
Expected Cap Life Time*
100Vac
230Vac
131,400hrs.
O/P: 24V, 5A, Ta: 25°C
105,121hrs 131,400hrs. O/P: 24V, 5A, Ta: 40°C
131,400hrs.
O/P: 24V, 2.5A, Ta: 40°C
*Estimated lifetime when 24 hours operating a day and E-cap’s manufacturer guarantee at 131,400 hrs (15 years) as maximum limit of lifetime.
6
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.
www.DeltaPSU.com (December 2016, Rev. 01)