TECHNICAL DATASHEET
CliQ II Buffer Module
24V 20A / DRB-24V020AB□
Reliability Data
MTBF(at Vin-1V Mode)
Expected Cap Life Time
Safety Standards / Directives
> 800,000 hrs. as per Telcordia SR-332 at Standby
Mode (Buffer Module in Ready State)
10 years (Standby Mode @ 40°C)
Electronic Equipment in Power Installations
Electrical Safety (Information Technology Equipment)
Industrial Control Equipment
Hazardous Location / ATEX
II 3G ATEX 94/9/EC;
IECEX Test Report
CE
Material and Parts
Galvanic Isolation
Input & Output to Ground
Signal to Ground
EN50718 / IEC62103
SIQ to EN60950-1, UL/cUL recognized to UL60950-1,
CSA C22.2 No. 60950-1, CB scheme to IEC60950-1
UL/cUL listed to UL508 and CSA C22.2 No. 107.1-01,
CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
CSA to CSA C22.2 No. 213-M1987, ANSI / ISA
12.12.01:2007 (Class I, Division 2, Group A, B, C, D, T4)
EN60079-0:2009, EN60079-15:2010
( II 3G Ex nA nC IIc T4 Gc)
Certificate No. ESP 12 ATEX 1 491 X
For IEC60079-0, IEC60079-15
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
RoHS Directive 2011/65/EU Compliant
1.5KVac
1.5KVac
EMC
EMC / Emissions
Component Power Supply for General Use
Immunity to
Electrostatic Discharge
Radiated Field
Electrical Fast Transient / Burst
Surge
Conducted
Power Frequency Magnetic Fields
Voltage Dips
Low Energy Pulse Test (Ring Wave)
EN61000-4-2
EN61000-4-3
EN61000-4-4
IEC6100-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
IEC61000-4-12
CISPR22, EN55022, EN55011, FCC Title 47: Class B
EN61204-3
EN55024, EN61000-6-2
Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Level 3 Criteria A1)
80MHz–1GHz, 10V/M with 1kHz tone / 80% modulation
Level 3 Criteria A1)
2kV
Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Level 3 Criteria A1)
10A/Meter
Level 3 Criteria A1)
Additional 100% dip; 1 cycle (20ms); No Damage
Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Note: Product intended to be used as Apparatus with AC-DC Power Supply, EMC compliance to be verified in correspondence to the connected units.
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
4
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (October 2013, Rev. 01)