CliQ II Buffer Module
24V 20A / DRB-24V020AB□
Connectable Power Supplies
The buffer module is recommended to be connected with the following power supplies:
CliQ Series
CliQ II Series
- DRP024V060W1AZ
- DRP024V060W1AA
- DRP024V120W1AA
- DRP024V240W1AA
- DRP024V480W1AA
- DRP024V060W3AA
- DRP024V120W3AA
- DRP024V240W3AA
- DRP024V480W3AA
– DRP024V060W1BA
– DRP024V120W1BA
– DRP024V240W1BA
– DRP024V480W1BA
More new products can be found at www.DeltaPSU.com
Inrush Current
Inrush current is the peak, instantaneous, input current measured
and occurs when input voltage is first applied. For DC input
voltage the maximum peak value of inrush will occur during the
first applied DC voltage.
Overload & Overcurrent Protections
When the output current exceeds 120% of IO (Max load) buffer
module will shut down and latch. Normal operation of buffer
module can be resumed upon removal of fault and power supply
input is recycled (ON/OFF) or input to buffer module is recycled.
Overvoltage Protection
The buffer module’s overvoltage protection will be activated when
DC input to the module exceeds the maximum specifed input
voltage. The overvoltage limits are same as power supply limits,
32V ± 10%. Buffer module will shut down and latch during
overvoltage mode, and will return to normal operation upon
removal of fault and power supply input is recycled (ON/OFF) or
input to buffer module is recycled.
Short Circuit Protection
Buffer module is protected by short circuit during buffering mode,
in the event of short circuit the module will shut down and latch.
Operation can be resumed upon removal of fault and power
supply input is recycled (ON/OFF) or input to buffer module is
recycled.
10
All parameters are specified at 25°C ambient unless otherwise noted.