English
Language : 

ES239 Datasheet, PDF (22/36 Pages) Cyrustek corporation – 6000 Counts DMM / Inrush
ES239
6000 Counts DMM / Inrush
2.1. Range
Push RANGE1 key to switch from automatic to manual mode, and while in manual mode, changes
the full-scale range. The following figure shows the state transition.
Automatic
Mode
1 push < 1 sec
1 push > 1 sec
Manual
Mode
Range up
1 push < 1 sec
Measurement Mode
Auto
V
VR2 – VR5
Manual
VRi → VRi + 1,
VR5 → VR1
Control Range
6.000V – 1000V
Auto µA
R1 – R2
R1 → R2,
R2 → R1
600.0µA – 6000µA
Auto mA
R1-R2
R1 → R2
R2 → R1
60.00mA – 600.0mA
Auto A
R1-R2
R1 → R2
R2 → R1
6.000A – 10.00A
Auto 60A/600A
(clamp)
R1-R2
R1 → R2
R2 → R1
60.00A – 600.0A
Auto 600A/6000A
(clamp)
R1-R2
R1 → R2
R2 → R1
600.0A – 6000A
Capacitance
C1 – C8
Ci → Ci + 1,
C8 → C1
6.000nF– 60.00mF
Capacitance (Clamp) C1 – C8
Ci → Ci + 1,
C8 → C1
6.000nF– 60.00mF
Ω
OR0 – OR6
ORi → ORi + 1,
OR6 → OR1
60.00Ω – 60.00MΩ
Temp
T1-T2
T1T2
T2T1
600.0oC~1350oC
Frequency
FR1 – FR7
FRi → FRi + 1
FR7 → FR1
600.0Hz – 60.00MHz
Note:
1. Pushing RANGE resets all existing special modes except for VAHZ mode.
2. Initial range of voltage mode depends on VST pin configuration
Initial Range
6.000V2
600.0µA
60.00mA
6.000A
60.00A
600.0A
6.000nF
6.000nF
60.00Ω
600.0oC
600.0Hz
V 2.2
22