English
Language : 

ES239 Datasheet, PDF (19/36 Pages) Cyrustek corporation – 6000 Counts DMM / Inrush
ES239
6000 Counts DMM / Inrush
1. Measurement Mode Switching
Measurement mode depends on the logic level of SLACDC, FC1, FC2, FC3, FC4, FC5 and KEY
selection. When FC5 is high, the measurement mode list is shown below:
SLACDC FC1 FC2 FC3 FC4
Mode
KEY selection
0
1
0
1
1
DC Voltage Measurement
0
1
1
0
1
23Auto DC Current Measurement(µA)
0
1
1
1
1
23Auto DC Current Measurement(mA)
0
0
0
0
0
23
Auto DC Current Measurement(A)
DCV ↔ ACV
DCA ↔ ACA
DCA ↔ ACA
DCA ↔ ACA
0
1
1
1
0
0
1
1
0
0
0
1
0
0
0
0
1
0
1
0
0
1
0
0
1
Scan RSDC
3Manual DC 6.000A
3Manual DC 60.00A
3Manual DC 600.0A
3Manual DC 6000A
Ω  Continuity  Diode  Cap  Scan
DCA ↔ ACA
DCA ↔ ACA
DCA ↔ ACA
DCA ↔ ACA
0
0
0
1
1
Resistance Measurement
Ω ↔ Continuity
0
0
0
0
1
Continuity Check
Continuity ↔ Diode
0
0
1
1
1
Resistance Measurement
Ω Continuity  Diode
0
0
0
1
0
Frequency Measurement
----
0
0
1
1
0
Capacitance Measurement
----
0
0
1
0
0
Auto Temperature Measurement
℃↔ ℉
0
0
1
0
1
DCmV
DCmV ↔ ACmV
1
1
0
1
1
AC Voltage Measurement
1
1
1
0
1
23
Auto AC Current Measurement(µA)
1
1
1
1
1
23
Auto AC Current Measurement(mA)
1
0
0
0
0
23
Auto AC Current Measurement(A)
ACV ↔ DCV
ACA ↔ DCA
ACA ↔ DCA
ACA ↔ DCA
1
1
1
1
0
EF mode
----
1
1
1
0
0
1
1
0
0
0
1
1
0
1
0
1
1
0
0
1
1
0
0
1
1
1
0
0
0
1
1
0
1
1
1
1
0
0
1
0
3Manual AC 6.000A
3Manual AC 60.00A
3Manual AC 600.0A
3Manual AC 6000A
1ADP0 ( 6000 )
1ADP1 ( 600.0 )
1
ADP2 ( 60.00 )
1
ADP3 ( 6.000 )
ACA ↔ DCA
ACA ↔ DCA
ACA ↔ DCA
ACA ↔ DCA
----
----
----
Set to LED mode if SEL2 is kept float
1
0
1
1
0
Capacitance Measurement (Clamp)
----
1
0
1
0
0
Auto Temperature Measurement
℉↔℃
1
0
1
0
1
ACmV
ACmV ↔ DCmV
Note:
1. When FC5 is high, the ADP0, ADP1, ADP2 and ADP3 modes can display minus sign.
2. These modes could be designed for multimeter current modes, please refer to section 1.4.
3. These modes could be designed for clampmeter current modes, please refer to section 1.5.
.
V 2.2
19
2015/12/15