English
Language : 

PALCE16V8 Datasheet, PDF (5/13 Pages) Advanced Micro Devices – EE CMOS 20-Pin Universal Programmable Array Logic
USE ULTRA37000™ FOR
ALL NEW DESIGNS
AC Test Loads and Waveforms
3.0V
GND
< 2 ns
ALL INPUT PULSES
90%
10%
90%
10%
< 2 ns
5V
PALCE16V8
OUTPUT
S1
R1
TEST POINT
R2
CL
Specification
tPD, tCO
tPZX, tEA
tPXZ, tER
S1
Closed
Z · H: Open
Z · L: Closed
H · Z: Open
L · Z: Closed
CL
50 pF
5 pF
Commercial
R1
200Ω
R2
390Ω
Military
R1
390Ω
R2
750Ω
Measured Output Value
1.5V
1.5V
H · Z: VOH – 0.5V
L · Z: VOL + 0.5V
Commercial and Industrial Switching Characteristics [2]
16V8-5
16V8-7
16V8-10
16V8-15
16V8-25
Parameter
Description
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit
tPD
Input to Output
Propagation Delay[8, 9]
1
5
3 7.5 3
10
3
15
3
25
ns
tPZX
OE to Output Enable
1
6
tPXZ
OE to Output Disable
1
5
tEA
Input to Output
Enable Delay[7]
1
6
6
10
15
20
ns
6
10
15
20
ns
9
10
15
25
ns
tER
Input to Output
Disable Delay[7, 10]
1
5
9
10
15
25
ns
tCO
Clock to Output Delay[8, 9] 1
4
2
5
2
7
2
10
2
12
ns
tS
Input or Feedback
3
5
7.5
12
15
ns
Set-up Time
tH
Input Hold Time
0
0
0
0
0
ns
tP
External Clock
Period (tCO + tS)
7
10
14.5
22
27
ns
Shaded areas contain preliminary information.
Notes:
8. Min. times are tested initially and after any design or process changes that may affect these parameters.
9. This specification is guaranteed for all device outputs changing state in a given access cycle.
10. This parameter is measured as the time after OE pin or internal disable input disables or enables the output pin. This delay is measured to the point at which a previous HIGH
level has fallen to 0.5 volts below VOH min. or a previous LOW level has risen to 0.5 volts above VOL max.
11. This specification indicates the guaranteed maximum frequency at which a state machine configuration with external feedback can operate.
12. This specification indicates the guaranteed maximum frequency at which the device can operate in data path mode.
13. This specification indicates the guaranteed maximum frequency at which a state machine configuration with internal only feedback can operate.
14. This parameter is calculated from the clock period at fMAX internal (1/fMAX3) as measured (see Note 7 above) minus tS.
Document #: 38-03025 Rev. *A
Page 5 of 13