English
Language : 

CPC7508 Datasheet, PDF (4/14 Pages) Clare, Inc. – Line Card Access Switch
CPC7508
1.6 Switch Specifications
1.6.1 Break Switches, SW1 and SW2
Parameter
Off-State
Leakage Current
On Resistance
On Resistance
Matching
DC current limit
Dynamic current limit
(t ≤ 0.5 μs)
Logic input to switch
output isolation
dv/dt sensitivity
Test Conditions
VSW1 (differential) = TLINE to TBAT
VSW2 (differential) = RLINE to RBAT
Applied voltage maximum ±225 V to ground
All-Off state.
+25° C, VSW (differential) = ±320 V
+85° C, VSW (differential) = ±330 V
-40° C, VSW (differential) = ±310 V
ISW(on) = ±10 mA, ±40 mA
+25° C
+85° C
-40° C
Per SW1 & SW2 On Resistance test
conditions.
VSW (on) = ±10 V, +25° C
VSW (on) = ±10 V, +85° C
VSW (on) = ±10 V, -40° C
Break switches on, all other switches off.
Apply ±1 kV 10x1000 μs pulse with
appropriate protection in place.
+25° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±225 V
VSW (TBAT, RBAT) = ±225 V
+85° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±225 V
VSW (TBAT, RBAT) = ±225 V
-40° C, Logic inputs = gnd,
VSW (TLINE, RLINE) = ±225 V
VSW (TBAT, RBAT) = ±225 V
-
Symbol
ISW
RON
ΔRON
ISW
ISW
ISW
-
Minimum
-
8
-
-
80
-
-
-
-
-
-
Typical
0.1
0.3
0.1
14.7
21.1
10.7
0.15
300
160
400
1.0
0.1
0.3
0.1
500
Maximum Unit
1
μA
-
28
Ω
-
0.8
Ω
-
mA
425
-
A
1
μA
-
V/μs
4
www.clare.com
R04