English
Language : 

CPC7508 Datasheet, PDF (3/14 Pages) Clare, Inc. – Line Card Access Switch
1. Specifications
CPC7508
1.1 Package Pinout
CPC7508
VDD 1
GND 2
TSD 3
N/C 4
16 INA
15 INB
14 INC
13 LATCH
TBAT 5
T 6 LINE
T 7 TEST_OUT
T 8 TEST_IN
12 RBAT
11 RLINE
10 RTEST_OUT
9 RTEST_IN
1.2 Pin Description
Pin Name
Description
1
VDD +12.5VDC supply
2
GND Ground
3
TSD I/O, All Off control, Thermal shutdown flag
4
N/C No Connect - Do not use
5
TBAT Tip lead to the SLIC
6
TLINE Tip lead of the line side
7 TTEST_OUT Tip lead of the Test Out (Drop Test) bus
8 TTEST_IN Tip lead of the Test In (Channel Test) bus
9 RTEST_IN Ring lead of the Test In (Channel Test) bus
10 RTEST_OUT Ring lead of the Test Out (Drop Test) bus
11
RLINE Ring lead of the line side
12
RBAT Ring lead to the SLIC
13 LATCH Input, Data latch enable
14
INC Input, Logic control
15
INB Input, Logic control
16
INA Input, Logic control
1.3 Absolute Maximum Ratings
Parameter
Minimum Maximum Unit
+12 V power supply (VDD)
-0.3
15
V
Logic input voltage
-0.3
6
V
Logic input to switch output
isolation
-
225
V
Switch open-contact to
ground isolation
-
225
V
Switch open, contact to
contact isolation
-
320
V
Operating relative humidity
5
95
%
Operating temperature
-40
+110
°C
Storage temperature
-40
+150
°C
Absolute maximum electrical ratings are at 25°C.
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
1.4 ESD Rating
ESD Rating (Human Body Model)
1000 V
1.5 General Conditions
Unless otherwise specified, minimum and maximum
values are guaranteed by production testing
requirements.
Typical values are characteristic of the device at 25° C
and are the result of engineering evaluations. They are
provided for information purposes only and are not
part of the testing requirements.
Specifications cover the operating temperature range
TA = -40° C to +85° C. Also, unless otherwise specified
all testing is performed with VDD = 12.5 Vdc, logic low
input voltage is 0 Vdc and logic high voltage is 3.3 Vdc.
R04
www.clare.com
3