English
Language : 

CS3318 Datasheet, PDF (8/44 Pages) Cirrus Logic – 8-Channel Analog Volume Control
CS3318
ANALOG CHARACTERISTICS
(Test conditions (unless otherwise specified): RS = 0; RL = 20 kΩ; CL = 20 pF; 10 Hz to 20 kHz Measurement
Bandwidth)
Parameter
Symbol Min
DC Characteristics
Step Size
-
Gain Error
(Vol = +22 dB)
-
Gain Matching Between Channels
(Vol = +22 dB)
-
Input Resistance
Input Capacitance
AC Characteristics
RIN
8
CIN
-
Total Harmonic Distortion + Noise
(Note 3) THD+N
-
Dynamic Range
121
Input/Output Voltage Range
Output Noise
(THD+N < 1 %) VFS (VA-) + 1.35
(Note 4)
-
Interchannel Isolation
(1 kHz)
-
Output Buffer
Offset Voltage
Output Resistance
AC Load Resistance
Load Capacitance
(Note 4) VOS
-
ROUT
-
RLOAD
2
-
Short Circuit Current
-
Unity Gain Bandwidth, Small Signal
-
Power Supplies
Supply Current (No Load, Vin = 0 V)
Normal Operation IVA+
-
IVA-
-
IVD
-
Power-Down, All Supplies (Note 5) IPD
-
Power Consumption
Normal Operation
-
Power Down (Note 5)
-
Power Supply Rejection Ratio (250 Hz)
PSRR
-
Typ
0.25
±0.5
±0.1
10
10
0.00025
127
-
1.8
-120
0.75
100
-
-
20
5
36
36
0.6
60
650
540
80
Max
Unit
-
dB
-
dB
-
dB
-
kΩ
-
pF
0.00063
-
(VA+) - 1.35
3.6
-
%
dB
V
μVrms
dB
5
mV
-
Ω
-
kΩ
100
pF
-
mA
-
MHz
50
mA
50
mA
1.07
mA
-
μA
904
mW
-
μW
-
dB
3. Vin = [(VFS Max - VFS Min) - 1.6 V] Vp-p, 1 kHz, Volume = 0 dB.
Note that for (VA+) = -(VA-) = 9 V, Vin = 13.7 Vp-p = 4.8 VRMS.
4. Measured with input grounded and volume = 0 dB. Will increase as a function of volume settings >0 dB.
5. Power-down is defined as RESET = low, all clock and data lines held static, and no analog input signals
applied.
8