Table 1 shows example volume settings using individual and master volume controls.
IndividualChX Master 1
Channel 1 +3.75 dB
Channel 2 +2.5 dB
Channel 3 +1.25 dB
Channel 4
Channel 5
0 dB
-1.25 dB
+1.0 dB
Channel 6 -2.5 dB
Channel 7 -3.75 dB
Channel 8 -4.0 dB
Mask 1ChX
0
0
0
0
1
1
1
1
Master 2
+5.25 dB
Mask 2ChX
0
0
1
1
0
0
1
1
Master 3
-8.5 dB
Mask 3ChX
0
1
0
1
0
1
0
1
LevelChX
+3.75 dB
-6.0 dB
+6.5 dB
-3.25 dB
-0.25 dB
-10.0 dB
+2.5 dB
-6.25 dB
Table 1. Example Volume Settings
Refer to Figure 6 on page 18 for a graphical representation of the volume controlsâ functionality.
Referenced Control
Register Location
Master X Volume................. âMaster 1 Volume - Address 11hâ on page 36
âMaster 2 Volume - Address 14hâ on page 37
âMaster 3 Volume - Address 17hâ on page 38
Master X Control ................. âMaster 1 Control - Address 12hâ on page 37
âMaster 2 Control - Address 15hâ on page 38
âMaster 3 Control - Address 18hâ on page 39
Master X Mask .................... âMaster 1 Mask - Address 10hâ on page 36
âMaster 2 Mask - Address 13hâ on page 37
âMaster 3 Mask - Address 16hâ on page 38
5.5.3
Volume Limits
The analog section of the CS3318 is designed to accommodate gain and attenuation over the range of
+22 dB to -96 dB. Values outside this range may, however, be written to the CS3318âs internal registers.
As shown in Figure 6 on page 18, the value of the Individual and Master volume control registers are
summed before being limited to the range allowed by the CS3318âs analog section. This architecture has
the benefit of allowing both individual and master volume control input beyond the analog range of the
CS3318.
If the effective volume (See Equation 1 on page 19) of an individual channel is greater than +22 dB, the
channelâs volume will be set to +22 dB.
If the effective volume of an individual channel is less than -96 dB, the channel will mute, but the MuteChX
bit will not be set. When the channelâs effective volume returns to -96 dB or above, the mute condition will
be released. It should be noted that if the channelâs MuteChX bit or any of the channelâs unmasked
Master X Mute bits are set, the channel will remain muted until the necessary mute conditions are re-
leased.
Referenced Control
Register Location
MuteChX ............................. âMute Control - Address 0Ahâ on page 33
Master X Mute..................... âMaster 1 Mute (Bit 1)â on page 37
âMaster 2 Mute (Bit 1)â on page 38
âMaster 3 Mute (Bit 1)â on page 39
20