English
Language : 

WM8310 Datasheet, PDF (77/291 Pages) Wolfson Microelectronics plc – Processor Power Management Subsystem
Pre-Production
ADDRESS
WM8310
BIT
LABEL
DEFAULT
DESCRIPTION
9:8 DC1_ON_M
ODE [1:0]
00
DC-DC1 ON Operating Mode
00 = Forced Continuous Conduction
Mode
01 = Auto Mode (Continuous /
Discontinuous Conduction with Pulse-
Skipping)
10 = LDO Mode
11 = Hysteretic Mode
6:2 DC1_ON_VS
EL [6:2]
1:0 DC1_ON_VS
EL [1:0]
00000
00
DC-DC1 ON Voltage select
DC1_ON_VSEL[6:0] selects the DC-
DC1 output voltage from 0.6V to 1.8V in
12.5mV steps.
DC1_ON_VSEL[6:2] also exist in
ICE/OTP memory, controlling the
voltage in 50mV steps.
DC1_ON_VSEL[6:0] is coded as
follows:
00h to 08h = 0.6V
09h = 0.6125V
…
48h = 1.4V (see note)
…
67h = 1.7875V
68h to 7Fh = 1.8V
Note - Maximum output voltage
selection in 4MHz switching mode is
48h (1.4V).
R16473 (4059h)
DC1 SLEEP
Control
15:13 DC1_SLP_S
LOT [2:0]
000
DC-DC1 SLEEP Slot select
000 = SLEEP voltage / operating mode
transition in Timeslot 5
001 = Disable in Timeslot 5
010 = Disable in Timeslot 4
011 = Disable in Timeslot 3
100 = Disable in Timeslot 2
101 = Disable in Timeslot 1
110 = SLEEP voltage / operating mode
transition in Timeslot 3
111 = SLEEP voltage / operating mode
transition in Timeslot 1
If DC-DC1 is assigned to a Hardware
Enable Input, then codes 001-101 select
in which timeslot the converter enters its
SLEEP condition.
9:8 DC1_SLP_M
00
DC-DC1 SLEEP Operating Mode
ODE [1:0]
00 = Forced Continuous Conduction
Mode
01 = Auto Mode (Continuous /
Discontinuous Conduction with Pulse-
Skipping)
10 = LDO Mode
11 = Hysteretic Mode
w
PP, May 2012, Rev 3.1
77