AA3-B0-10-450-1B1-C Datasheet, PDF (9/24 Pages) Carling Technologies – Circuit Breaker
A-Series Rocker UL489A – Ordering Scheme | 9
A
1
Series
F
2
Actuator
1
3
Poles
—B
4
Circuit
0 — 14 — 450 — 1
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
3
9
Actuator
Color
1 —M
10
Mounting/
Barriers
11
Max. Appl.
Rating
T
12
Agency
Approval
1 SERIES
A
2 ACTUATOR1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
Single color
J
Vertical legend
K Horizontal legend
Push-To-Reset, Visi-Rocker
N Indicate OFF,
vertical legend
O Indicate OFF,
horizontal legend
Push-To-Reset , Single color
R Vertical legend
U Horizontal legend
8 TERMINAL5
16 Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
37 Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
57 Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B Screw M5 w/upturned lugs
F Screw M5 w/upturned lugs
and 30° bend
G Screw M5 (Bus Type)
and 30° bend
H Screw M5 (Bus Type)
M7 M6 Threaded Stud
P8 Printed Circuit Board Terminals
Q9 Push-In Stud
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
Visi-Color10
ON-OFF
Dual10
Single Color
Visi-Rocker
White
B
1
Black
White
Black
D
2
White
n/a
Red
G
3
White
Red
Green
J
4
White
Green
Blue
L
5
White
Blue
Yellow
N
6
Black
Yellow
Gray
Q
7
Black
Gray
Orange
S
8
Black
Orange
3 POLES2
1
One
2
Two
3
Three
4 CIRCUIT
B Series Trip (Current)
5 AUXILIARY/ALARM SWITCH3
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
8
S.P.S.T., 0.187 Q.C. Term.
9
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
52 DC, Short,Hi-Inrush
54 DC, Medium, Hi-Inrush
56 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
285 0.850
215 0.150
290 0.900
220 0.200
295 0.950
225 0.250
410 1.000
230 0.300
512 1.250
235 0.350
415 1.500
240 0.400
517 1.750
245 0.450
420 2.000
250 0.500
522 2.250
255 0.550
527 2.750
260 0.600
430 3.000
265 0.650
435 3.500
270 0.700
440 4.000
275 0.750
445 4.500
280 0.800
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613
614
615
616
617
618
620
622
624
625
630
6354
6404
6454
6504
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
10 MOUNTING/BARRIERS11
STANDARD ROCKER BEZEL BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm
no
B
ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm
no
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
without Rockerguard (single pole units only)
no
H
with Rockerguard (single pole units only)
no
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
9
without Rockerguard (single pole units only)
no
J
with Rockerguard (single pole units only)
no
11 MAXIMUM APPLICATION RATING
M 80 DC
12 AGENCY APPROVAL
T
UL489A LISTED
K
UL489A LISTED, VDE CERTIFIED
J
UL489A LISTED, TUV CERTIFIED
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or
mixed poles, and have one rocker per breaker.
3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells.
30-50A are supplied with extended boat (B-Style) half shells.
4 VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, M and Q.
6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only TUV or VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL489A Listing.
9 Terminal Code Q not available with VDE certification.
10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O.
Rockerguard available with actuator codes C through K
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231