AA3-B0-10-450-1B1-C Datasheet, PDF (17/24 Pages) Carling Technologies – Circuit Breaker
A-Series Rocker UL Recognized – Ordering Scheme | 17
A F 1 — B 0 — 24 — 630 — 2 3 1 — D
1
Series
2
3
Actuator Poles
4
Circuit
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
11
Agency
Approval
1 SERIES
A
2 ACTUATOR1
Two Color Visi-Rocker
C Indicate ON, vertical legend
D Indicate ON, horizontal legend
E Indicate ON, no legend
F Indicate OFF, vertical legend
G Indicate OFF, horizontal legend
H Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N Indicate OFF,
vertical legend
O Indicate OFF,
horizontal legend
P Indicate OFF,
no legend
Single color
J
Vertical legend
K Horizontal legend
L No legend
Push-To-Reset , Single color
R Vertical legend
U Horizontal legend
V No legend
3 POLES
1
One
2
Two
3
Three
8 TERMINAL11
112 Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
313 Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
513 Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B Screw M5 w/upturned lugs
C Screw M4 w/upturned lugs
E13 Screw M4 (Bus Type)
F Screw M5 w/upturned lugs
and 30° bend
G Screw M5 (Bus Type)
and 30° bend
H13 Screw M5 (Bus Type)
L14 0.250 Q.C./ Solder Lug
M13 M6 Threaded Stud
P15 Printed Circuit BoardTerminals
Q16 Push-In Stud
R Screw M4 w/upturned lugs
and 30° bend
S17 Push-On 0.110 Tab (Q.C.)
T Screw M4 (Bus Type)
and 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
Visi-Color12
I-O ON-OFF
Dual12 Single Color
Visi-Rocker
White
A
B
1
Black
White
Black
C
D
2
White
n/a
Red
F
G
3
White
Red
Green
H
J
4
White
Green
Blue
K
L
5
White
Blue
Yellow
M
N
6
Black
Yellow
Gray
P
Q
7
Black
Gray
Orange
R
S
8
Black
Orange
4 CIRCUIT
A3 Switch Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D4 Shunt Trip (Current)
E4 Shunt Trip (Voltage)
F4 Relay Trip (Current)
G4 Relay Trip (Voltage)
H4,5 Dual Coil with Shunt Trip
Voltage Coil
K4,5 Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY/ALARM SWITCH6,7
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
6
S.P.S.T., 0.139 Solder Lug
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
8
S.P.S.T., 0.187 Q.C. Term.
9
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
429 50/60Hz Short, Hi-Inrush
449 50/60Hz Medium, Hi-Inrush
469 50/60Hz Long, Hi-Inrush
529 DC, Short,Hi-Inrush
549 DC, Medium, Hi-Inrush
569 DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
225 0.250
420 2.000
025 0.025
230 0.300
522 2.250
030 0.030
235 0.350
527 2.750
035 0.035
240 0.400
430 3.000
040 0.040
245 0.450
435 3.500
045 0.045
250 0.500
440 4.000
050 0.050
255 0.550
445 4.500
055 0.055
260 0.600
450 5.000
060 0.060
265 0.650
455 5.500
065 0.065
270 0.700
460 6.000
070 0.070
275 0.750
465 6.500
075 0.075
280 0.800
470 7.000
080 0.080
285 0.850
475 7.500
085 0.085
290 0.900
480 8.000
090 0.090
295 0.950
485 8.500
095 0.095
410 1.000
490 9.000
210 0.100
512 1.250
495 9.500
215 0.150
415 1.500
610 10.000
220 0.200
517 1.750
710 10.500
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8
A06 6 DC
A32 32 DC
J12 12 AC
A12 12 DC
A48 48 DC
J18 18 AC
A18 18 DC
A65 65 DC
J24 24 AC
A24 24 DC
J06 6 AC
J48 48 AC
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
63510 35.000
64010 40.000
64510 45.000
65010 50.000
J65 65 AC
K20 120 AC
L40 240 AC
10 MOUNTING/BARRIERS20
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm
no
B
ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm
no
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” wide bezel
8
without Rockerguard (single pole units only)
no
H
with Rockerguard (single pole units only)
no
FRONT PANEL SNAP-IN BRACKET, 0.96” wide bezel
9
without Rockerguard (single pole units only)
no
J
with Rockerguard (single pole units only)
no
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles,
and have one rocker per breaker.
3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole
(Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction,
Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and
are rated for intermittent duty only.
6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard
half shells. 30-50A are supplied with extended boat (B-Style) half shells.
7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted
& TUV Certified to 50 amps.
10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only.
UL Recognition & CSA Accepted available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only
available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30
amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M
(M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE
Certified when the washers are used.
14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE
Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C.
Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL
Recognition and CSA Certification with Circuit Codes A, B and C.
16 Terminal Code Q not available with VDE.
17 Terminal Code S used on voltage coil circuit constructions only.
18 Color shown is visi and legend with remainder of rocker black.
19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on
Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard
available with actuator codes C through L.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231