English
Language : 

AA3-B0-10-450-1B1-C Datasheet, PDF (6/24 Pages) Carling Technologies – Circuit Breaker
6 | A-Series Handle UL Recognized – Ordering Scheme
A
1
Series
A
2
Actuator
3
3
Poles
—B
4
Circuit
0 — 10 — 450 — 1
5
Aux/Alarm
Switch
6
Frequency
& Delay
7
Current Rating
8
Terminal
B
9
Actuator
Color
1—C
10
Mounting/
Barriers
11
Agency
Approval
1 SERIES
A
2 ACTUATOR1
A Handle, one per pole
B Handle, one per multipole unit
S Mid-Trip Handle, one per pole
T Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
One
2
Two
3
Three
4
Four
5
Five
6
Six
4 CIRCUIT
A2 Switch Only (No Coil)
B Series Trip (Current)
C Series Trip (Voltage)
D3 Shunt Trip (Current)
E3 Shunt Trip (Voltage)
F3 Relay Trip (Current)
G3 Relay Trip (Voltage)
H3,4 Dual Coil with Shunt Trip
Voltage Coil
K3,4 Dual Coil with Relay Trip
Voltage Coil
5 AUXILIARY/ALARM SWITCH5
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
6
S.P.S.T., 0.139 Solder Lug
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
8
S.P.S.T., 0.187 Q.C. Term.
9
S.P.D.T., 0.187 Q.C. Term.
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
427 50/60Hz Short, Hi-Inrush
447 50/60Hz Medium, Hi-Inrush
467 50/60Hz Long, Hi-Inrush
527 DC, Short,Hi-Inrush
547 DC, Medium, Hi-Inrush
567 DC, Long, Hi-Inrush
Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles
5 pole - three handles at center poles
6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with
circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps,
select Current Code 630. For 35 - 50 amps, select Current Code 650.
3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum.
4 Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with
standard half shells. 35-50A - supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.
6 Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
8 VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSA Accepted available in one and two pole breakers.
9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q..
10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Certification up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat
Washers. These breakers are only VDE Certified when the washers are used.
12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted
available up to 30A.
13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit
Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are
available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C.
14 Terminal Code Q not available with VDE certification.
15 Single pole only.
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
225 0.250
025 0.025
230 0.300
030 0.030
235 0.350
035 0.035
240 0.400
040 0.040
245 0.450
045 0.045
250 0.500
050 0.050
255 0.550
055 0.055
260 0.600
060 0.060
265 0.650
065 0.065
270 0.700
070 0.070
275 0.750
075 0.075
280 0.800
080 0.080
285 0.850
085 0.085
290 0.900
090 0.090
295 0.950
095 0.095
410 1.000
210 0.100
512 1.250
215 0.150
415 1.500
220 0.200
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)6
CODE AMPERES
A06 6 DC
A32 32 DC
J12 12 AC
A12 12 DC
A48 48 DC
J18 18 AC
A18 18 DC
A65 65 DC
J24 24 AC
A24 24 DC
J06 6 AC
J48 48 AC
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6358
6408
6458
6508
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65 65 AC
K20 120 AC
L40 240 AC
8 TERMINAL9
110 Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
311 Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
511 Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B Screw M5 w/upturned lugs
C Screw M4 w/upturned lugs
E11 Screw M4 (Bus Type)
F Screw M5 w/upturned lugs
and 30° bend
G Screw M5 (Bus Type)
and 30° bend
H11 Screw M5 (Bus Type)
L12 0.250 Q.C./ Solder Lug
M11 M6 Threaded Stud
Q14 Push-In Stud
R Screw M4 w/upturned lugs
and 30° bend
T11 Screw M4 (Bus Type)
and 30° bend
P13 Printed Circuit Board
Terminals
S13 Push-On 0.110 Tab (Q.C.)
9 ACTUATOR COLOR & LEGEND
Acuator Color
I-O
ON-OFF
White
A
B
Black
C
D
Red
F
G
Green
H
J
Blue
K
L
Yellow
M
N
Gray
P
Q
Orange
R
S
Black (short handle)15 T
U
Dual
1
2
3
4
5
6
7
8
9
Legend Color
Black
White
White
White
White
Black
Black
Black
White
10 MOUNTING/BARRIERS
MOUNTING STYLE BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 x 0.195 inches
yes
2
ISO M3 x 5mm
no
B
ISO M3 x 5mm (multipole only)
yes
Front panel Snap-In, 0.75” wide bezel
5
without Handleguard no
6
without Handleguard (multipole only)
yes
Front panel Snap-In, 0.96” wide bezel
7
without Handleguard, 1-pole 0.96” wide;
no
multipole units have .105” bezel overhang on all sides
8
without Handleguard, 1-pole 0.96” wide;
yes
(multipole only) .105” bezel overhang on all sides
11 AGENCY APPROVAL
C UL Recognized & CSA Accepted
D VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com