English
Language : 

HCPL-316J Datasheet, PDF (7/33 Pages) AVAGO TECHNOLOGIES LIMITED – 2.5 Amp Gate Drive Optocoupler with Integrated (VCE) Desaturation Detection and Fault Status Feedback
Regulatory Information
The HCPL-316J has been approved by the following
organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
UL
Recognized under UL 1577, component recognition pro-
gram, File E55361.
CSA
Approved under CSA Component Acceptance Notice #5,
File CA 88324.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
  for rated mains voltage ≤ 150 Vrms
I - IV
  for rated mains voltage ≤ 300 Vrms
I - IV
  for rated mains voltage ≤ 600 Vrms
I - III
Climatic Classification
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b**
  VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
  Partial Discharge < 5 pC
VIORM
VPR
891
1670
VPEAK
VPEAK
Input to Output Test Voltage, Method a**
  VIORM x 1.5 = VPR, Type and Sample Test, tm = 60 sec,
  Partial Discharge < 5 pC
VPR
1336
VPEAK
Highest Allowable Overvoltage** (Transient Overvoltage tini = 10 sec)
Safety-limiting values – maximum values allowed in the event of a failure,
  also see Figure 2.
  Case Temperature
  Input Power
  Output Power
Insulation Resistance at TS, VIO = 500 V
VIOTM
6000
TS
PS, INPUT
PS, OUTPUT
RS
175
400
1200
>109
VPEAK
°C
mW
mW
Ω
*Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application. Sur-
face mount classification is class A in accordance with CECCOO802.
**Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section IEC/
EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
1400
1200
1000
PS, OUTPUT
PS, INPUT
800
600
400
200
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – °C
Figure 2. Dependence of safety limiting values on temperature.
HCPL-316J fig 2