English
Language : 

HCTL-1100 Datasheet, PDF (6/40 Pages) Agilent(Hewlett-Packard) – General Purpose Motion Control ICs
AC Electrical Characteristics
VDD = 5 V ± 5%; TA = -20°C to +85°C; Units = nsec
ID
#
Signal
Symbol
Clock Frequency
2 MHz
1 MHz
Min. Max. Min. Max.
Formula*
Min. Max.
1 Clock Period (clk)
2 Pulse Width, Clock High
3 Pulse Width, Clock Low
4 Clock Rise and Fall Time
5 Input Pulse Width Reset
6 Input Pulse Width Stop, Limit
tCPER
500
1000
tCPWH
230
300
tCPWL
200
200
200
tCR
50
50
50
tIRST
2500
5000
5 clk
tIP
600
1100
1 clk
+ 100 ns
7 Input Pulse Width Index, Index
tIX
1600
3100
3 clk
+ 100 ns
8 Input Pulse Width CHA, CHB
tIAB
1600
3100
3 clk
+ 100 ns
9 Delay CHA to CHB Transition
10 Input Rise/Fall Time CHA, CHB,
Index
tAB
tIABR
600
1100
1 clk
+ 100 ns
450
900
900 (clk
< 1 MHz)
11 Input Rise/Fall Time Reset, ALE,
CS, OE, Stop, Limit
tIR
50
50
50
12 Input Pulse Width ALE, CS
tIPW
80
80
80
13 Delay Time, ALE Fall to CS Fall
tAC
50
50
50
14 Delay Time, ALE Rise to CS Rise
tCA
50
50
50
15 Address Setup Time Before
ALE Fall
tASR1
20
20
20
16 Address Setup Time Before CS
tASR
20
20
20
Fall
17 Write Data Setup Time Before
CS Rise
18 Address/Data Hold Time
19 Setup Time, R/W Before CS Rise
20 Hold Time, R/W After CS Rise
21 Delay Time, Write Cycle, CS
Rise to ALE Fall
22 Delay Time, Read/Write, CS
Rise to CS Fall
23 Write Cycle, ALE Fall to ALE
Fall For Next Write
tDSR
20
tH
20
tWCS
20
tWH
20
tCSAL 1700
tCSCS 1500
tWC
1830
20
20
20
20
3400
3000
3530
20
20
20
20
3.4 clk
3 clk
3.7 clk
6