English
Language : 

HCTL-1100 Datasheet, PDF (2/40 Pages) Agilent(Hewlett-Packard) – General Purpose Motion Control ICs
Applications
Typical applications for the
HCTL-1100 include printers,
medical instruments, material
handling machines, and industrial
automation.
Note: Avago Technologies
encoders are not recommended
for use in safety critical
applications. Eg. ABS braking
systems, power steering, life
support systems and critical care
medical equipment. Please
contact sales representative if
more clarification is needed.
HCTL-1100 vs. HCTL-1000
The HCTL-1100 is designed to
replace the HCTL-1000. Some
differences exist, and some
enhancements have been added.
System Block Diagram
Comparison of HCTL-1100 and HCTL-1000
Description
HCTL-1100
HCTL-1000
Max. Supply Current
30 mA
180 mA
Max. Power Dissipation
165 mW
950 mW
Max. Tri-State Output
Leakage Current
150 nA
10 µA
Operating Frequency
100 kHz-2 MHz 1 MHz-2 MHz
Operating Temperature
Range
-20°C to +85°C 0°C to 70°C
Storage Temperature Range -55°C to +125°C - 40°C to +125°C
Synchronize 2 or More ICs Yes
–
Preset Actual Position
Registers
Yes
–
Read Flag Register
Yes
–
Limit and Stop Pins
Must be pulled
up to V if
DD
not used.
Can be left
floating if not
used.
Hard Reset
Required
Recommended
PLCC Package Available
Yes
–
2