HCPL-M600500 Datasheet, PDF (4/11 Pages) AVAGO TECHNOLOGIES LIMITED – Small Outline, 5 Lead, High CMR, High Speed, Logic Gate Optocouplers
Insulation and Safety Related Specifications
Parameter
Symbol
Minimum External Air Gap
(External Clearance)
L(101)
Minimum External
Tracking (External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
L(102)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
Value
5
5
0.08
175
IIIa
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage d 150 Vrms
I – IV
for rated mains voltage d 300 Vrms
I – III
Climatic Classification
55/85/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
VIORM
VPR
560
1050
Vpeak
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.5=VPR, Type and Sample Test, tm=60 sec,
Partial discharge < 5 pC
VPR
840
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini =10 sec)
VIOTM
6000
Vpeak
Safety-limiting values – maximum values allowed in the event
of a failure.
Case Temperature
Input Current**
Output Power**
TS
150
°C
IS, INPUT
150
mA
PS, OUTPUT
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
:
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of PS and IS on ambient temperature.
Recommended Operating Conditions
Parameter
Symbol Min.
Max.
Units
Input Current, Low Level
Input Current, High Level
Supply Voltage, Output
Fan Out (RL = 1 kΩ)
Output Pull-Up Resistor
Operating Temperature
IFL*
0
IFH**
5
VCC
4.5
N
RL
330
TA
-40
250
15
5.5
5
4,000
85
μA
mA
V
TTL Loads
Ω
°C
* The off condition can also be guaranteed by ensuring that VF(off ) ≤ 0.8 volts.
** The initial switching threshold is 5mA or less. It is recommended that 6.3mA to 10mA be used for best performance and to permit at least a
20% LED degradation guardband.