English
Language : 

HCTL-2017 Datasheet, PDF (3/12 Pages) AVAGO TECHNOLOGIES LIMITED – Quadrature Decoder/Counter Interface ICs
Operating Characteristics
Table 1. Absolute Maximum Ratings
(All voltages below are referenced to VSS)
Parameter
DC Supply Voltage
Input Voltage
Storage Temperature
Operating Temperature [1]
Symbol
VDD
VIN
TS
TA
Table 2. Recommended Operating Conditions
Parameter
DC Supply Voltage
Ambient Temperature [1]
Symbol
VDD
TA
Limits
-0.3 to +6.0
-0.3 to (VDD +0.3)
-40 to +100
-40 to +85
Units
V
V
°C
°C
Limits
4.5 to 5.5
-40 to +85
Units
V
°C
Table 3. DC Characteristics VDD = 5V ± 5%; TA = -40 to 85°C
Symbol
Parameter
Condition
Min Typ Max Unit
VIL [2]
VIH [2]
VT+
VT-
VH
IIN
Low-Level Input Voltage
High-Level Input Voltage
Schmitt-Trigger Positive-Going Threshold
Schmitt-Trigger Negative-Going Threshold
Schmitt-Trigger Hysteresis
Input Current
VIN=VSS or VDD
1.5
V
3.5
V
3.5 4.0 V
1.0 1.5
V
1.0 2.0
V
-10 1
+10 µA
VOH [2]
VOL [2]
IOZ
High-Level Output Voltage
Low-Level Output Voltage
High-Z Output Leakage Current
IOH = -3.75 mA
IOL = +3.75mA
VO=VSS or VDD
2.4 4.5
V
0.2 0.4
V
-10 1
+10 µA
IDD
Quiescent Supply Current
VIN=Vss or VDD
1
10
µA
CIN [3]
COUT [3]
Input Capacitance
Output Capacitance
Any Input
Any Output
5
PF
5
PF
Notes:
1. Free Air
2. In general, for any VDD between the allowable limits (+4.5V to +5.5V), VIL = 0.3VDD and VIH = 0.7VDD; typical values are VOH = VDD –
0.5V and VOL = VSS + 0.2V
3. Including package capacitance but excluding PCB capacitance.
3