English
Language : 

ATR2406_06 Datasheet, PDF (6/25 Pages) ATMEL Corporation – Low-IF 2.4-GHz ISM Transceiver
6. Electrical Characteristics
VS = 3.6V with AUX regulator, Tamb = 25°C, unless otherwise specified
No. Parameters
Test Conditions
Symbol
Min.
Typ. Max. Unit
1 Supply
1.1 Supply voltage
With AUX regulator
VS
1.2 Supply voltage
Without AUX regulator
VS
1.3 RX supply current
CW mode (peak current)
Burst mode at 10 Kbits/s(4)
IS
IS
1.4 TX supply current
CW mode (peak current)
Burst mode at 10 Kbits/s(4)
IS
IS
Battery lifetime of a remote
See Section 10. ”Appendix:
1.5 control application using an
AVR®
Current Calculations for a Remote
Control” on page 20
3.2
3.6
4.6
V
2.9
3.0
3.6
V
57
mA
625
µA
42
mA
500
µA
1.6
Supply current in power-down
mode
With AUX regulator
PU_TRX = 0; PU_REG = 0
IS
<1
µA
1.7
Supply current in power-down
mode
Without AUX regulator
PU_TRX = 0; PU_REG = 0
IS
<1
µA
2 Voltage Regulator
2.1 AUX regulator
VREG
3.0
V
2.2 VCO regulator
VREG_VCO
2.7
V
3 Transmitter Part
3.1 TX data rate
72/144/288/576/1152
kBits/s
3.2 Output power
PTX
4
dBm
3.3 TX data filter clock
3.4 Frequency deviation
3.5 Frequency deviation scaling(3)
9 taps in filter
To be tuned by GFCS bits
GFFM = GFFM_nom × GFCS
(Refer to bus protocol D9 to D11)
fTXFCLK
GFFM_nom
GFCS
10.368/13.824
±400
60
130
MHz
kHz
%
3.6 Frequency drift
3.7 Harmonics
With standard loop filter and slot
length of 1400 µs (Refer to the
application note “ATR2406 Loop
Filter and Data Rates”)
BW = 100 kHz(1)
∆fo (drift)
±40
kHz
–41.2 dBm
Spurious emissions
30 – 1000 MHz
3.8 1 – 12.75 GHz
1.8 – 1.9 GHz
5.15 – 5.3 GHz
BW = 100 kHz(1)
–57
dBm
–57
dBm
–57
dBm
–57
dBm
4 Ramp Generator, Pin 21
4.1 Minimum output voltage
TX_ON = low
Vmin
0.7
V
4.2 Maximum output voltage
Refer to bus protocol D12 to D13
Vmax
1.1
1.9
V
4.3 Rise time
tr
5
µs
4.4 Fall time
tf
5
µs
Notes: 1. Measured and guaranteed only on the Atmel® evaluation board, including microstrip filter, balun, and Smart Radio Fre-
quency (Smart RF) firmware. Conducted measured.
2. Timing is determined by external loop filter characteristics. Faster timing can be achieved by modification of the loop filter.
For further information refer to the application notes.
3. The Gaussian filter control setting (GFCS) is used to compensate production tolerances by tuning the modulation deviation
in production to the nominal value of 400 kHz.
4. Burst mode with 0.9% duty cycle
6 ATR2406
4779L–ISM–09/06