SAM9N12/SAM9CN11/SAM9CN12
33.6.3.7
33.6.3.8
register.This flag is cleared by writing to the UDP_ICR register. Then the device enters Suspend
Mode.
In this state bus powered devices must drain less than 500uA from the 5V VBUS. As an exam-
ple, the microcontroller switches to slow clock, disables the PLL and main oscillator, and goes
into Idle Mode. It may also switch off other devices on the board.
The USB device peripheral clocks can be switched off. Resume event is asynchronously
detected. MCK and UDPCK can be switched off in the Power Management controller and the
USB transceiver can be disabled by setting the TXVDIS field in the UDP_TXVC register.
Warning: Read, write operations to the UDP registers are allowed only if MCK is enabled for the
UDP peripheral. Switching off MCK for the UDP peripheral must be one of the last operations
after writing to the UDP_TXVC and acknowledging the RXSUSP.
Receiving a Host Resume
In suspend mode, a resume event on the USB bus line is detected asynchronously, transceiver
and clocks are disabled (however the pullup shall not be removed).
Once the resume is detected on the bus, the WAKEUP signal in the UDP_ISR is set. It may gen-
erate an interrupt if the corresponding bit in the UDP_IMR register is set. This interrupt may be
used to wake up the core, enable PLL and main oscillators and configure clocks.
Warning: Read, write operations to the UDP registers are allowed only if MCK is enabled for the
UDP peripheral. MCK for the UDP must be enabled before clearing the WAKEUP bit in the
UDP_ICR register and clearing TXVDIS in the UDP_TXVC register.
Sending a Device Remote Wakeup
In Suspend state it is possible to wake up the host sending an external resume.
• The device must wait at least 5 ms after being entered in suspend before sending an external
resume.
• The device has 10 ms from the moment it starts to drain current and it forces a K state to
resume the host.
• The device must force a K state from 1 to 15 ms to resume the host
To force a K state to the bus (DDM at 3.3V and DDP tied to GND), it is possible to use a transis-
tor to connect a pullup on DDM. The K state is obtained by disabling the pullup on DDP and
enabling the pullup on DDM. This should be under the control of the application.
Figure 33-15. Board Schematic to Drive a K State
3V3
PIO
0: Force Wake UP (K State)
1: Normal Mode
1.5 K
11063G–ATARM–09-Oct-12
DM
555