English
Language : 

AP89341_15 Datasheet, PDF (8/24 Pages) Aplus Intergrated Circuits – Integrated Circuits Inc
Integrated Circuits Inc. aP89341/170/085
Fig. 7 Edge, Unholdable, Non-retrigger
Fig. 8 Edge, Holdable
Fig. 9 SBT sequential trigger with Edge Holdable and Unholdable
TRIGGER MODES
There are three trigger modes available for aP89341/170/085 series which are determined by setting
M1 and M2 pins to logic HIGH or LOW.
• Key Trigger Mode (M1=0; M0=0);
• CPU Parallel Trigger Mode (M1=0; M0=1);
• CPU Serial Command Mode (M1=1; M0=0);
Ver 5.0
7
Aug 23, 2010