EP53A8LQA Datasheet, PDF (13/21 Pages) Altera Corporation – Integrated Inductor
maximum total capacitance on the output,
including the output filter capacitor and bulk
and decoupling capacitance, at the load, is
given as:
EP53A8LQA:
COUT_TOTAL_MAX = COUT_Filter + COUT_BULK =
250uF
EP53A8HQA:
COUT_TOTAL_MAX = COUT_Filter + COUT_BULK =
125uF
EP53A8LQA (in external divider mode):
COUT_TOTAL_MAX = 2.25x10-4/VOUT Farads
The nominal value for COUT is 10uF. See the
applications section for more details.
Over Current/Short Circuit Protection
The current limit function is achieved by
sensing the current flowing through a sense P-
MOSFET which is compared to a reference
current. When this level is exceeded the P-
FET is turned off and the N-FET is turned on,
pulling VOUT low. This condition is maintained
for approximately 0.5mS and then a normal
soft start is initiated. If the over current
condition still persists, this cycle will repeat.
EP53A8LQA/EP53A8HQA
Under Voltage Lockout
During initial power up, an under voltage
lockout circuit will hold-off the switching
circuitry until the input voltage reaches a
sufficient level to insure proper operation. If
the lockout circuitry will again disable the
switching. Hysteresis is included to prevent
chattering between states.
Enable
The ENABLE pin provides a means to shut
down the converter or enable normal
operation. A logic low will disable the
converter and cause it to shut down. A logic
high will enable the converter into normal
operation.
NOTE: The ENABLE pin must not be left
floating.
Thermal Shutdown
When excessive power is dissipated in the
chip, the junction temperature rises. Once the
junction temperature exceeds the thermal
shutdown temperature, the thermal shutdown
circuit turns off the converter output voltage
thus allowing the device to cool. When the
junction temperature decreases by 25C°, the
device will go through the normal startup
process.
10366
July 21, 2015
www.altera.com/enpirion, Page 13
Rev D