English
Language : 

LU3X54FT Datasheet, PDF (32/54 Pages) Agere Systems – QUAD-FET (Fast Ethernet Transceiver) for 10Base-T/100Base-TX/FX
LU3X54FT
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Management Registers (MR) (continued)
Table 12. MR1—Status Register Bit Descriptions
Register/Bit1
1.15 (T4ABLE)
1.14 (TXFULDUP)
1.13 (TXHAFDUP)
1.12 (ENFULDUP)
1.11 (ENHAFDUP)
1.10:7 (RESERVED)
1.6 (NO_PA_OK)
1.5 (NWAYDONE)
1.4 (REM_FLT)
1.3 (NWAYABLE)
1.2 (LSTAT_OK)
1.1 (JABBER)
1.0 (EXT_ABLE)
Type2
R
R
R
R
R
R
R
R
R
R
R
R
R
Description
100Base-T4 Ability. This bit will always be a 0.
0: Not able.
1: Able.
100Base-TX Full-Duplex Ability. This bit will always be a 1.
0: Not able.
1: Able.
100Base-TX Half-Duplex Ability. This bit will always be a 1.
0: Not able.
1: Able.
10Base-T Full-Duplex Ability. This bit will always be a 1.
0: Not able.
1: Able.
10Base-T Half-Duplex Ability. This bit will always be a 1.
0: Not able.
1: Able.
Reserved. All bits will read as a 0.
Suppress Preamble. This bit is set to a 1 indicating that the LU3X54FT accepts
management frames with the preamble suppressed.
Autonegotiation Complete. When this bit is a 1, it indicates the autonegotia-
tion process has been completed. The contents of registers MR4, MR5, MR6,
and MR7 are now valid. The default value is a 0. This bit is reset when autone-
gotiation is started.
Remote Fault. When this bit is a 1, it indicates a remote fault has been
detected. This bit will remain set until cleared by reading the register. The default
is a 0.
Autonegotiation Ability. When this bit is a 1, it indicates the ability to perform
autonegotiation. The value of this bit is always a 1.
Link Status. When this bit is a 1, it indicates a valid link has been established.
This bit has a latching function: a link failure will cause the bit to clear and stay
cleared until it has been read via the management interface.
Jabber Detect. This bit will be a 1 whenever a jabber condition is detected. It
will remain set until it is read, and the jabber condition no longer exists.
Extended Capability. This bit indicates that the LU3X54FT supports the
extended register set (MR2 and beyond). It will always read a 1.
1. Note that the format for the bit descriptions is as follows: the first number is the register number, the second number is the bit position in the
register, and the name of the instantiated pad is in capital letters.
2. R = read.
32