English
Language : 

APT50M75JLLU2 Datasheet, PDF (6/6 Pages) Advanced Power Technology – Power MOS 7TM is a new generation of low loss, high voltage, N-Channel enhancement mode power MOSFETS.
APT50M75JLLU2
Vr
30µH
D.U.T.
trr/Qrr
Waveform
+15v
PEARSON 411
0v
ICAL -15v
diF/dt Adjust
CURRENT
TRANSFORMER
Figure 22, Diode Reverse Recovery Test Circuit and Waveforms
ECHN N 1 IF - Forward Conduction Current
E T TIO 2
diF
/dt
-
Current
Current
Slew Rate, Rate of Forward
Change Through Zero Crossing.
1
4
C A Zero
VAN RM 3 IRRM - Peak Reverse Recovery Current.
5
D O 4 trr - Reverse Recovery Time Measured from Point of IF
F { } Current Falling Through Zero to a Tangent Line 6 diM/dt
3
0.5 IRRM
A IN Extrapolated Through Zero Defined by 0.75 and 0.50 IRRM.
2
0.75 IRRM
6
5 Qrr - Area Under the Curve Defined by IRRM and trr.
6 diM/dt - Maximum Rate of Current Change During the Trailing Portion of trr.
Qrr = 1/2 (trr . IRRM)
Figure 23, Diode Reverse Recovery Waveform and Definitions
SOT-227 (ISOTOP®) Package Outline
r = 4.0 (.157)
(2 places)
31.5 (1.240)
31.7 (1.248)
7.8 (.307)
8.2 (.322)
W=4.1 (.161)
W=4.3 (.169)
H=4.8 (.187)
H=4.9 (.193)
(4 places)
4.0 (.157)
4.2 (.165)
(2 places)
11.8 (.463)
12.2 (.480)
8.9 (.350)
9.6 (.378)
Hex Nut M4
(4 places)
25.2 (0.992)
0.75 (.030) 12.6 (.496) 25.4 (1.000)
0.85 (.033) 12.8 (.504)
14.9 (.587)
15.1 (.594)
30.1 (1.185)
30.3 (1.193)
38.0 (1.496)
38.2 (1.504)
3.3 (.129)
3.6 (.143)
Cathode
1.95 (.077)
2.14 (.084)
Drain
Changed 2/10/99
Source
Gate
Dimensions in Millimeters and (Inches)
ISOTOP® is a Registered Trademark of SGS Thomson.
"UL Recognized" File No. E145592
APT's devices are covered by one or more of the following U.S.patents: 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336
5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058