DYNAMIC CHARACTERISTICS
APT15GP1 60BDF1
Symbol Characteristic
Test Conditions
MIN
Cies Input Capacitance
Capacitance
Coes Output Capacitance
VGE = 0V, VCE = 25V
Cres Reverse Transfer Capacitance
f = 1 MHz
VGEP Gate-to-Emitter Plateau Voltage
Gate Charge
Qg
Total Gate Charge 3
Qge Gate-Emitter Charge
Qgc Gate-Collector ("Miller ") Charge
VGE = 15V
VCE = 300V
IC = 15A
SSOA Switching Safe Operating Area
TJ = 150°C, RG = 5Ω, VGE = 65
15V, L = 100µH,VCE = 600V
td(on)
tr
td(off)
tf
Eon1
Eon2
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4
Turn-on Switching Energy (Diode) 5
Inductive Switching (25°C)
VCC = 400V
VGE = 15V
IC = 15A
RG = 5Ω
TJ = +25°C
Eoff
Turn-off Switching Energy 6
td(on)
tr
td(off)
tf
Eon1
Eon2
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4 4
Turn-on Switching Energy (Diode) 55
Inductive Switching (125°C)
VCC = 400V
VGE = 15V
IC = 15A
RG = 5Ω
TJ = +125°C
Eoff
Turn-off Switching Energy 66
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol Characteristic
MIN
RΘJC
RΘJC
WT
Junction to Case (IGBT)
Junction to Case (DIODE)
Package Weight
TYP
1685
210
15
7.5
55
12
15
MAX
UNIT
pF
V
nC
A
8
12
ns
29
58
130
152
µJ
121
8
12
ns
69
88
130
267
µJ
268
TYP MAX UNIT
.50
°C/W
1.31
5.90 gm
1 Repetitive Rating: Pulse width limited by maximum junction temperature.
2 For Combi devices, Ices includes both IGBT and FRED leakages
3 See MIL-STD-750 Method 3471.
4 Eon1 is the clamped inductive turn-on-energy of the IGBT only, without the effect of a commutating diode reverse recovery current
adding to the IGBT turn-on loss. (See Figure 24.)
5 Eon2 is the clamped inductive turn-on energy that includes a commutating diode reverse recovery current in the IGBT turn-on switching
loss. A Combi device is used for the clamping diode as shown in the Eon2 test circuit. (See Figures 21, 22.)
6 Eoff is the clamped inductive turn-off energy measured in accordance with JEDEC standard JESD24-1. (See Figures 21, 23.)
APT Reserves the right to change, without notice, the specifications and information contained herein.