6. ABSOLUTE MAXIMUM RATINGS
Table 3. Absolute Maximum Ratings
(Do not exceed these limits to prevent damage to the device. Exposure to absolute maximum rating conditions for long periods may affect device
reliability.)
PARAMETER
VALUE
UNIT
VHM, DRM to VSS
-0.3 to 54
V
VP to VSS
-0.3 to 20
V
CSM, REGO to VSS
VSYS, AIO6/.. to VSS
-0.3 to VP + 0.3
V
-0.3 to 6
V
VCC33 to VSS
-0.3 to 4.1
V
VCC18 to VSS
-0.3 to 2.5
V
AIOx/.. (except AIO6/..), VCCIO to VSS
-0.3 to VSYS + 0.3
V
PDx/.., PEx/.. to VSS
-0.3 to VCCIO + 0.3
V
PCx/.. to VSS
-0.3 to VCC33 + 0.3
V
DRLx to VSS
-0.3 to VP + 0.3
V
DXBx to VSS
-0.3 to 630
V
DXSx to VSS
-11 to 610
V
DXSx allowable offset slew rate (dVDXSx/dt)
DXBx, DXHx to respective DXSx
-50 to 50
V/ns
-0.3 to 22
V
VSS, VSYS, DRM, DRLx, DXHx, REGO RMS current(1)
VP RMS current(1)
Operating temperature range
0.2
0.6
-40 to 105
ARMS
ARMS
°C
Human body model (JEDEC)
2
kV
Electrostatic discharge (ESD)
Charge device model (JEDEC)
800
V
Machine model (JEDEC)
(1) Peak current can be 10 times higher than RMS value for pulses shorter than 10µs.
200
V
- 11 -
Rev 1.18‒December 29, 2016