English
Language : 

PAC5223 Datasheet, PDF (11/67 Pages) Active-Semi, Inc – Power Application Controller
PAC5223
Power Application Controller
6. ABSOLUTE MAXIMUM RATINGS
Table 3. Absolute Maximum Ratings
(Do not exceed these limits to prevent damage to the device. Exposure to absolute maximum rating conditions for long periods may affect device
reliability.)
PARAMETER
VALUE
UNIT
VHM, DRM to VSSP
-0.3 to 72
V
VP to VSS
-0.3 to 20
V
CSM, REGO to VSS
-0.3 to VP + 0.3
V
VSYS, AIO6/.. to VSS
-0.3 to 6
V
VCC33 to VSS
-0.3 to 4.1
V
VCC18 to VSS
-0.3 to 2.5
V
AIOx/.. (except AIO6/..), VCCIO to VSS
PDx/.., PEx/.. to VSS
PCx/.. to VSSA
DRLx to VSSP
DRBx to VSSP
-0.3 to VSYS + 0.3
V
-0.3 to VCCIO + 0.3
V
-0.3 to VCC33 + 0.3
V
-0.3 to VP + 0.3
V
-0.3 to 84
V
DRSx to VSSP
-6 to 72
V
DRSx allowable offset slew rate (dVDRSx/dt)
5
V/ns
DRBx, DRHx to respective DRSx
-0.3 to 20
V
VSSP, VSSA to VSS
-0.3 to 0.3
V
VSS, VSYS, DRM, DRLx, DRHx, REGO RMS current(1)
0.2
ARMS
VSSP RMS current(1)
0.4
ARMS
VP RMS current(1)
Operating temperature range
0.6
-40 to 105
ARMS
°C
Human body model (JEDEC)
2
kV
Electrostatic discharge (ESD)
Charge device model (JEDEC)
1
kV
Machine model (JEDEC)
(1) Peak current can be 10 times higher than RMS value for pulses shorter than 10µs.
200
V
- 11 -
Rev 1.10‒January 28, 2016