English
Language : 

X9118_14 Datasheet, PDF (12/17 Pages) Intersil Corporation – Single Digitally-Controlled Potentiometer
X9118
Equivalent A.C. Load Circuit
5V
1533Ω
3V
867Ω
SDA OUTPUT
100pF
SDA OUTPUT
100pF
SPICE MACROMODEL
RTOTAL
RH
RL
CL
CW
CL
10pF
10pF
25pF
RW
AC Timing High-Voltage Write Cycle Timing
SYMBOL
PARAMETER
fSCL
tCYC
tHIGH
tLOW
tSU:STA
tHD:STA
tSU:STO
tSU:DAT
tHD:DAT
tR
tF
tAA
tDH
tI
tBUF
tSU:WPA
tHD:WPA
Clock Frequency
Clock Cycle Time
Clock High-Time
Clock Low-Time
Start Setup Time
Start Hold Time
Stop Setup Time
SDA Data Input Setup Time
SDA Data Input Hold Time
SCL and SDA Rise Time
SCL and SDA Fall Time
SCL Low to SDA Data Output Valid Time
SDA Data Output Hold Time
Noise Suppression Time Constant at SCL and SDA inputs
Bus Free Time (Prior to Any Transmission)
A0, A1 Setup Time
A0, A1 Hold Time
High-Voltage Write Cycle Timing
SYMBOL
PARAMETER
tWR
High-Voltage Write Cycle Time (store instructions)
XDCP Timing
SYMBOL
tWRPO
tWRL
PARAMETER
Wiper Response Time After the Third (last) Power Supply is Stable
Wiper Response Time After Instruction Issued (all load instructions)
MIN
2500
600
1300
600
600
600
100
30
250
0
50
1300
0
0
MAX
400
300
300
UNITS
kHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
TYP
MAX
UNITS
5
10
ms
TYP
UNITS
8
µs
8
µs
Submit Document Feedback 12
FN8161.5
April 9, 2014