Absolute Maximum Ratings
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Voltage on SCL, SDA, or Any Address Input
with Respect to VSS. . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
Voltage on V+ (referenced to VSS) (Note 8) . . . . . . . . . . . . . . . .10V
Voltage on V- (referenced to VSS) (Note 8) . . . . . . . . . . . . . . . . -10V
(V+) – (V-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12V
Any Voltage on RH/RL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V+
Any Voltage on RL/RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V-
IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Supply Voltage (VCC) Limits (Note 8)
X9118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ±10%
X9118-2.7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Thermal Information
Thermal Resistance (Typical, Note 3, 4) . θJA (°C/W) θJC (°C/W)
14 Ld TSSOP . . . . . . . . . . . . . . . . . . . .
92
25
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Power Rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mW
Wiper current (max) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3mA
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
3. θJA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
4. For θJC, the “case temp” location is taken at the package top center.
Analog Specifications
TA = +25°C, unless otherwise noted. Boldface limits apply across the operating temperature range , -40°C to +85°C.
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
MAX
(Note 10) TYP (Note 10) UNITS
RTOTAL
End to End Resistance
End to End Resistance Tolerance
100
kΩ
±20
%
RW
Wiper Resistance
RW
Wiper Resistance
Vv+
Voltage on V+ Pin
IW = (VRH - VRL)/RTOTAL, VCC = 3V, VRL = -3V
150
500
Ω
IW = (VRH - VRL)/RTOTAL, VCC = 5V, VRL = 0V
40
100
Ω
X9118 (Note 8)
+4.5
+5.5
V
X9118-2.7 (Note 8)
+2.7
+5.5
V
Vv-
Voltage on V- Pin
X9118
-5.5
-4.5
V
X9118-2.7
-5.5
-2.7
V
VTERM
Voltage on any RH or RL Pin
Noise
VSS = 0V
Ref: 1kHz
V-
V+
V
-120
dBV
Resolution
0.1
%
Absolute Linearity (Note 5)
Rw(n)(actual) – Rw(n)(expected), where n = 1 to
1023
±1.5
MI
(Note 7)
Relative Linearity (Note 6)
Rw(m + 1) – [Rw(m) + MI], where m = 1 to 1023
±1.5
MI
(Note 7)
Temperature Coefficient of RTOTAL
Ratiometric Temperature
Coefficient
Wiper at middle point
±300
±20
ppm/°C
ppm/°C
CH/CL/CW Potentiometer Capacitances
See Macro model
10/10
pF
/25
NOTES:
5. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
6. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
7. MI = RTOT/1023 or (RH – RL)/1023, single pot.
8. VCC, V+, V- must reach their final values within 1ms of each other.
9. n = 0, 1, 2, …,1023; m = 0, 1, 2, …, 1022.
Submit Document Feedback 10
FN8161.5