Mixed-Mode Clock Manager (MMCM) Module (v1.00a)
Table 1: Configuration Parameters for MMCM Module (Cont’d)
Parameter Name
Description
Allowed
Values
C_CLKIN1_PERIOD
This parameter passes the value to the Same as
equivalent attribute of the MMCM_ADV MMCM_ADV
C_CLKOUT0_BUF...
C_CLKOUT6_BUF
If C_CLKOUTn_BUF = true, a BUFG is
inserted between the CLKOUTn pin of the
MMCM_ADV primitive and CLKOUTn
output
true, false
C_CLKOUT0_USE_FINE
_PS...
C_CLKOUT6_USE_FINE
_PS
This parameter passes the value to the
equivalent attribute of the MMCM_ADV
true, false
C_CLKOUT0_DIVIDE_F
This parameter passes the value to the
equivalent attribute of the MMCM_ADV
Same as
MMCM_ADV
C_CLKOUT1_DIVIDE... This parameter passes the value to the Same as
C_CLKOUT6_DIVIDE equivalent attribute of the MMCM_ADV MMCM_ADV
C_CLKOUT0_DUTY_CY
CLE...
C_CLKOUT6_DUTY_CY
CLE
This parameter passes the value to the
equivalent attribute of the MMCM_ADV
Same as
MMCM_ADV
C_CLKOUT0_PHASE... This parameter passes the value to the Same as
C_CLKOUT6_PHASE equivalent attribute of the MMCM_ADV MMCM_ADV
CLKOUT4_CASCADE
This parameter passes the value to the
equivalent attribute of the MMCM_ADV
true, false
C_COMPENSATION
This parameter passes the value to the Same as
equivalent attribute of the MMCM_ADV MMCM_ADV
C_DIVCLK_DIVIDE
This parameter passes the value to the Same as
equivalent attribute of the MMCM_ADV MMCM_ADV
C_REF_JITTER1
This parameter passes the value to the Same as
equivalent attribute of the MMCM_ADV MMCM_ADV
CLOCK_HOLD
This parameter passes the value to the
equivalent attribute of the MMCM_ADV
true, false
STARTUP_WAIT
This parameter passes the value to the
equivalent attribute of the MMCM_ADV
true, false
C_EXT_RESET_HIGH
IF C_EXT_RESET_HIGH = 0, the RST
signal is inverted before connecting to the 0,1
MMCM_ADV
C_FAMILY
Target FPGA family
virtex6
Default
Value
0.000
Type
real
false
Boolean
false
Boolean
1.000
1
real
integer
0.500
real
0.000
real
false
Boolean
ZHOLD
string
1
integer
0.010
real
false
Boolean
false
Boolean
1
virtex6
integer
string
Allowable Parameter Combinations
The MMCM module has the same restrictions on parameter combinations that are documented for the
MMCM_ADV primitive in the Virtex-6 User Guide and Virtex-6 Libraries Guide.
Note: The MMCM Module wrapper does not perform any error checking to enforce the design rules
and restrictions described in the Virtex-6 User Guide.
MMCM Module I/O Signals
The input and output signals of the MMCM module are described in Table 2.
DS737 June 24, 2009
www.xilinx.com
3
Product Specification