English
Language : 

X76F100 Datasheet, PDF (8/17 Pages) Xicor Inc. – 1K 128 x 8 Bit
X76F100
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ....................–65°C to +135°C
Storage temperature ........................–65°C to +150°C
Voltage on any pin with
respect to VSS......................................... –1V to +7V
D.C. output current ............................................... 5mA
Lead temperature (soldering, 10 seconds).........300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
Max.
+70°C
+85°C
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification) is
not implied. Exposure to absolute maximum rating con-
ditions for extended periods may affect device reliability.
Supply Voltage
X76F100
X76F100-3
Limits
4.5V to 5.5V
3.0V to 5.5V
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Symbol
ICC1
ICC2(3)
ISB1(1)
ISB2(1)
ILI
ILO
VIL(2)
VIH(2)
VOL
Parameter
VCC Supply Current
(Read)
VCC Supply Current
(Write)
VCC Supply Current
(Standby)
VCC Supply Current
(Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Limits
Min.
Max. Unit
1
mA
3
mA
1
µA
1
µA
10
µA
10
µA
–0.5 VCC x 0.3 V
VCC x 0.7 VCC + 0.5 V
0.4
V
Test Conditions
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 kHz,
SDA = Open
RST = CS = VSS
fSCL = VCC x 0.1/VCC x 0.9 Levels @ 400 kHz,
SDA = Open
RST = CS = VSS
VIL = VCC x 0.1, VIH = VCC x 0.9
fSCL = 400 kHz, fSDA = 400 kHz
VSDA = VSCC = VCC
Other = GND or VCC–0.3V
VIN = VSS to VCC
VOUT = VSS to VCC
IOL = 3mA
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Symbol
COUT(3)
CIN(3)
Test
Output Capacitance (SDA)
Input Capacitance (RST, SCL, CS)
Max.
8
6
Unit
pF
pF
Conditions
VI/O = 0V
VIN = 0V
Notes: (1) Must perform a stop command after a read command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not tested.
(3) This parameter is periodically sampled and not 100% tested.
REV 1.0 6/22/00
www.xicor.com
Characteristics subject to change without notice. 8 of 16