English
Language : 

X76F100 Datasheet, PDF (10/17 Pages) Xicor Inc. – 1K 128 x 8 Bit
X76F100
Nonvolatile Write Cycle Timing
Symbol
tWC(1)
Parameter
Write Cycle Time
Min.
Typ.(1)
5
Max.
10
Unit
ms
Note: (1) tWC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle.
It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used.
Bus Timing
SCL
SDA IN
tSU:STA
tF
tHIGH
tLOW
tHD:STA
tHD:DAT
tSU:DAT
tR
tSU:STO
SDA OUT
tAA
tDH
tBUF
Write Cycle Timing
SCL
SDA
8th Bit of Last Byte
ACK
CS Timing Diagram (Selecting/Deselecting the Part)
Stop Condition
tWC
Start Condition
SCL
CS from
Master
tSU:CS
tHD:CS
REV 1.0 6/22/00
www.xicor.com
Characteristics subject to change without notice. 10 of 16