Read Operation
Prior to issuing the Slave Address Byte with the R/W bit
set to one, the master must first perform a “dummy” write
operation. The master issues the start condition and the
Slave Address Byte, receives an acknowledge, then
issues the Word Address Bytes. After acknowledging
receipts of the Word Address Bytes, the master immedi-
ately issues another start condition and the Slave
Address Byte with the R/W bit set to one. This is followed
by an acknowledge from the device and then by the eight
bit word. The master terminates the read operation by not
responding with an acknowledge and then issuing a stop
condition. See Figure 12 for the address, acknowledge,
and data transfer sequence.
Figure 9. Read Sequence
S
S
Signals from t
Slave
the Master
a
r
Address
Byte
Address
t
Slave
a Address
r
S
t
o
t
t
p
SDA Bus
1 01 10 0 0 1 111 1 1 11
1
Signals from
the Slave
A
A
C
C
K
K
A
C
K
Data
Stops and Write Modes
Stop conditions that terminate write operations must be
sent by the master after sending at least 1 full data byte
plus the subsequent ACK signal. If a stop is issued in
the middle of a data byte, or before 1 full data byte plus
its associated ACK is sent, then the device will reset
itself without performing the write. The contents of the
array will not be effected.
Acknowledge Polling
The disabling of the inputs during high voltage cycles
can be used to take advantage of the typical 5ms write
cycle time. Once the stop condition is issued to indicate
the end of the master’s byte load operation, the device
initiates the internal high voltage cycle. Acknowledge
polling can be initiated immediately. To do this, the
master issues a start condition followed by the Slave
Address Byte for a write or read operation. If the device
is still busy with the high voltage cycle then no ACK will
be returned. If the device has completed the write oper-
ation, an ACK will be returned and the host can then
proceed with the read or write operation. See Figure
12.
Serial Read Operations
Read operations are initiated in the same manner as
write operations with the exception that the R/W bit of
the Slave Address Byte is set to one. There are three
basic read operations: Current Address Reads, Ran-
dom Reads, and Sequential Reads.
Current Address Read
Internally the device contains an address counter that
maintains the address of the last word read incre-
mented by one. Therefore, if the last read was to
address n, the next read operation would access data
from address n+1. On power up, the address of the
address counter is undefined, requiring a read or write
operation for initialization.
Upon receipt of the Slave Address Byte with the R/W
bit set to one, the device issues an acknowledge and
then transmits the eight bits of the Data Byte. The mas-
ter terminates the read operation when it does not
respond with an acknowledge during the ninth clock
and then issues a stop condition. See Figure 13 for the
address, acknowledge, and data transfer sequence.
REV 1.3.4 7/12/02
www.xicor.com
Characteristics subject to change without notice. 10 of 25