English
Language : 

X28HC64 Datasheet, PDF (10/24 Pages) Xicor Inc. – 5 Volt, Byte Alterable E2PROM
X28HC64
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X28HC64 ..................................... –10°C to +85°C
X28HC64I, X28HC64M ............. –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
Respect to VSS ....................................... –1V to +7V
D.C. Output Current ............................................. 5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
Industrial
Military
0°C
–40°C
–55°C
+70°C
+85°C
+125°C
3857 PGM T02.1
Supply Voltage
X28HC64
Limits
5V ±10%
3857 PGM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Symbol
Parameter
ICC
VCC Current (Active)
(TTL Inputs)
ISB1 VCC Current (Standby)
(TTL Inputs)
ISB2 VCC Current (Standby)
(CMOS Inputs)
ILI
ILO
VlL(2)
VIH(2)
VOL
VOH
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Min.
–1
2
2.4
Limits
Typ.(1)
15
Max.
40
Units
mA
1
2
mA
100
200
µA
±10
µA
±10
µA
0.8
V
VCC + 1 V
0.4
V
V
Test Conditions
CE = OE = VIL, WE = VIH, All
I/O’s = Open, Address Inputs =
TTL Levels @ f = 10 MHz
CE = VIH, OE = VIL
All I/O’s = Open, Other Inputs = VIH
CE = VCC – 0.3V, OE = GND
All I/O’s = Open, Other Inputs =
VCC – 0.3V
VIN = VSS to VCC
VOUT = VSS to VCC, CE = VIH
IOL = 5mA
IOH = –5mA
3857 PGM T04.2
Notes: (1) Typical values are for TA = 25°C and nominal supply voltage
(2) VIL min. and VIH max. are for reference only and are not tested.
10