WM8352
ADDRESS
R145 (91h)
Digitiser Control
(2)
BIT
13:12
LABEL
AUXADC_MASK
MODE [1:0]
10:8 AUXADC_CRAT
E [2:0]
Table 115 Initiating AUXADC Measurements
DEFAULT
00
000
Production Data
DESCRIPTION
AUXADC MASK input control
00 = MASK is ignored
01 = When MASK is asserted, all
AUXADC measurements are
inhibited.
10 = Reserved
11 = MASK input initiates AUXADC
measurements. AUXADC_POLL
and AUXADC_CTC have no effect.
MASK polarity is controlled by
GPn_CFG.
AUXADC measurement frequency
in Continuous mode
000 = 1Hz
001 = 4Hz
010 = 8Hz
011 = 16Hz
100 = 32Hz
101 = 64Hz
110 = 128Hz
111 = 256Hz
In Polling mode, setting AUXADC_POLL = 1 initiates one set of measurements, after which the
AUXADC waits for a new trigger.
In Continuous mode, a set of measurements will be initiated at the frequency set by
AUXADC_CRATE.
When using MASK to initiate measurements (AUXADC_MASKMODE=11), a rising edge (if
GPn_CFG = 1) or a falling edge (if GPn_CFG = 0) initiates one set of AUXADC measurements. The
MASK signal must be asserted for long enough for the AUXADC to perform all the selected
measurements.
The AUXADC_SELn bits should not be changed until all previous measurement results stored in the
AUXn readback registers have been read.