English
Language : 

W83637HF_06 Datasheet, PDF (70/151 Pages) Winbond – LPC I/O
W83637HF/HG
Register Location:
Power on Default Value
Attribute:
Size:
5Ah
00h
Read Only
8 bits
7654
32 1 0
VIN2_STS
Reserved
Reserved
FAN3_STS
CASE_STS
VTIN_STS
TAR1_STS
TAR2_STS
Bit 7: Smart Fan 2 warning status. Set 1, the CPUTIN temperature has been over the target
temperature for 3 minutes with full fan speed at thermal cruise mode of SmartFanTM. Set 0, the
temperature does not reach the warning range yet.
Bit 6: Smart Fan 1 warning status. Set 1, the SYSTIN temperature has been over the target
temperature for 3 minutes with full fan speed at thermal cruise mode of SmartFanTM. Set 0, the
temperature does not reach the warning range yet.
Bit 5: VTIN temperature sensor status. Set 1, the temperature exceeds the over-temperature limit
value. Set 0, the temperature is in under the hysteresis value.
Bit 4: Case Open Status. Set 1, the case open is detected and latched. Set 0, the case is not latched
open.
Bit 3: FAN 2 Status. Set 1, the fan speed counter is over the limit value. Set 0, the fan speed counter
is in the limit range.
Bit 2-1: Reserved.
Bit 0: Vin2 Voltage Status. Set 1, the voltage of VIN2 is over the limit value. Set 0, the voltage of VIN2
is in the limit range.
Real Time Hardware Status Register III -- Index 5Bh (Bank 4)
- 65 -
Publication Release Date: March, 2006
Revision 1.6