English
Language : 

W83L786NR Datasheet, PDF (29/50 Pages) Winbond – H/W Monitoring IC
W83L786NR/ W83L786NG
8.6 Register - Index 45h
Power on default [7:0] = 0000, 0000 b
BIT
NAME
READ/WRITE
7-0 Reserved
Read/write
Reserved.
DESCRIPTION
8.7 Register - Index 46h
Power on default [7:0] = 0000, 0000 b
BIT
NAME
READ/WRITE
7-0 Reserved
Read/write
Reserved
DESCRIPTION
8.8 GPIO/GPO Function Enable Control Register - Index 47h
Power on default [7:0] = 0000, 0000 b
BIT
NAME
READ/WRITE
DESCRIPTION
7 EN_GPIO2
Read/Write
Pin 2 Function Select.
<0> - Function of Pin 2 is TEMP_FAULT#.
<1> - Function of Pin 2 is GPIO2.
6 EN_GPIO1
Read/Write
Pin 1 Function Select.
<0> - Function of Pin 1 is FAN_FAULT#.
<1> - Function of Pin 1 is GPIO1.
5 EN_GPIO7
4-3 Reserved
Read/Write
Read/Write
Pin 20 Function Select.
<0> - Function of Pin 20 is VOLTAGE_FAULT#.
<1> - Function of Pin 20 is GPIO7.
Reserved
2 EN_GPIO6
Read/Write
Pin 18 Function Select.
<0> - Function of Pin 18 is PWM/DC_OUT2.
<1> - Function of Pin 18 is GPIO6.
1 EN_GPIO5
Read/Write
Pin 9 Function Select.
<0> - Function of Pin 9 is FANIN2.
<1> - Function of Pin 9 is GPIO5.
0 EN_GPO3
&4
Read/Write
Enable GPO3 & GPO4 Function of Pin 6 & Pin7.
<0> - Functions of GPO3 & GPO4 are disabled.
<1> - Functions of GPO3 & GPO4 are enabling.
8.9 Register - Index 48h
Reserved
- 24 -