English
Language : 

W83L786NR Datasheet, PDF (25/50 Pages) Winbond – H/W Monitoring IC
W83L786NR/ W83L786NG
7.7.1.2. Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status Register.
Once an interrupt event has occurred by exceeding TO, then reset, if the temperature remains above
the THYST, the interrupt will not occur. (Figure 14-2)
7.7.1.3. One-Time Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will not cause
an interrupt. Once an interrupt event has occurred by exceeding TO, then going below THYST, an
interrupt will not occur again until the temperature exceeding TO. (Figure 14-3)
TOI
TOI
THYST
THYST
SMI#
SMI#
**
**
*
*
*Interrupt Reset when Interrupt Status Registers are read
*
*
Figure 14-1. Comparator Interrupt Mode
Figure 14-2. Two-Times Interrupt Mode
TO I
TH Y S T
S M I#
*
*
* In te rru p t R e s e t w h e n In te rru p t S ta tu s R e g is te rs a re re a d
F ig u re 1 4 -3 . O n e -T im e In te rru p t M o d e
- 20 -