W83L786NR Datasheet, PDF (24/50 Pages) Winbond – H/W Monitoring IC
W83L786NR/ W83L786NG
REGISTER
Non-Stop Duty Cycle
Duty Level 1
Duty Level 2
Duty Level 3
Temp Point 1
Temp Point 2
Temp Point 3
Temp Point 4
Tolerance
D+, D- – FAN1
CR[81h] b3:b0
CR[81h] b7:b4
CR[82h] b3:b0
CR[82h] b7:b4
CR[83h] b7:b0
CR[84h] b7:b0
CR[85h] b7:b0
CR[86h] b7:b0
CR[8Dh] b3:b0
VTIN1 – FAN2
CR[87h] b3:b0
CR[87h] b7:b4
CR[88h] b3:b0
CR[88h] b7:b4
CR[89h] b7:b0
CR[8Ah] b7:b0
CR[8Bh] b7:b0
CR[8Ch] b7:b0
CR[8Dh] b7:b4
7.6.5 Fan Fault (FAN_FAULT #)
W83L786NR/NG provides a good protection for fan speed. Set Pin 1 (FAN_FAULT#) to monitor fan
speed. When FANIN1 (Pin8) or FANIN2 (Pin9) exceeds fan count high limit in VR3B or VR3C. Pin1
FAN_FAULT# will be asserted (Figure 13).
F an co u n t lim it
FA N _FA U LT#
F ig u re 1 3 . F A N _ F A U L T
7.7 Fault Signal—INT#
7.7.1 Temperature
Pin INT# for temperature has 3 modes.
7.7.1.1. Comparator Interrupt Mode
Temperature exceeding TO causes an interrupt and this interrupt will be reset when reading all of the
Interrupt Status Registers. Once an interrupt event has occurred by exceeding TO, then reset, if the
temperature remains above the THYST, the interrupt will occur again when the next conversion has
completed. If an interrupt event has occurred by exceeding TO and not reset, the interrupts will not
occur again. The interrupts will continue to occur in this manner until the temperature goes below
THYST. (Figure 14-1)