English
Language : 

W93910 Datasheet, PDF (25/35 Pages) Winbond – ERMES PAGING DECODER
W93910
pc1 pc0
00
01
10
11
Table 27. Paging category index
Paging category
Tone only
Numeric
Alphanumeric
transparent data
The ain3−ain0 is used to indicated the alert type of the message, except in the remote programming
situation.
ain3−ain0
Alert type description
0000
non-urgent alert type 0
0001
non-urgent alert type 1
0010
non-urgent alert type 2
0011
non-urgent alert type 3
0100
non-urgent alert type 4
0101
non-urgent alert type 5
0110
non-urgent alert type 6
0111
non-urgent alert type 7
1000
urgent alert type 0
1001
urgent alert type 1
1010
urgent alert type 2
1011
urgent alert type 3
1100
urgent alert type 4
1101
urgent alert type 5
1110
urgent alert type 6
1111
urgent alert type 7
Table 28. Alert type index
CMW for remote programming
When the pager receives the remote programming message, the W93910 will program the internal
remote programming addresses automatically, and will also inform the µC by sending out the received
message. For remote programming, the cm3−cm0 of CMW is equal to 1010, the f1−f0 and ain3−ain0 of
CMD, and rd17−rd0 of MDW will send out the received programming message to µC as shown below.
- 25 -
Publication Release Date: Auguest 1999
Revision A1