English
Language : 

W93910 Datasheet, PDF (24/35 Pages) Winbond – ERMES PAGING DECODER
W93910
CMW Description:
cm3− cm0
0000
1000
1001
1010
1100
1101
1110
1111
Others
message type description
individual call
long message w/o C.S--First submessage.
long message w/o C.S--Others submessage.
remote programming
retransmit latest message no#
long message with C.S--Others submessage.
long message with C.S--First submessage.
Change Character Set (C.S.)
Reserved
Table 23. Message type description (cm3−cm0)
eb
External flag
0
Home Receiver
1
External receiver
Table 24. External receiver index
g1 g0
00
01
10
11
RIC address index of received message
IA17−IA0 available
Air Programming RIC
GIA17−GIA0 available
Group call by CTAP method
Table 25. Received message address index
mn4−mn0
00000
Others
Message number
For group calls the reserved dummy value 00000 shall be used. The reserved
dummy value may also be used when the message numbering is deactivated,
as with remote programming.
For individual calls the initial value shall be 00001; then mn4−mn0 will be
increased by 1 continuously for the following message.
Table 26. Message number description (mn4−mn0)
- 24 -