W78E378 Datasheet, PDF (16/38 Pages) Winbond – MONITOR MICROCONTROLLER
Preliminary W78E378/W78C378/W78C374
DDC1/SIO1 and SIO2 Ports
1. DDC1/SIO1 port
DDC Port
SIO1
IN
SCL
OUT
SCL
ENDDC1
IN
SDA OUT
0
Support DDC2B/2B+
1
DDC1
SDA
OUT
SCL Vsync
Support DDC1
SDA
• ENDDC1 = 1, used as DDC1 (Display Data Channel) port:
To support DDC1, use Vsync signal for shift clock and P3.0 (SDA) for data output.
• ENDDC1 = 0, used as SIO1 port:
To support DDC2B/2B+/2Bi/2AB, use P3.1 (SCL) for serial clock and P3.0 (SDA) for serial data.
SCLINT interrupt is generated when SCL (P3.1) has a high-to-low transition and then keeps at low for
16 × 1/Fosc.
Fosc
8 MHz
10 MHz
SCL low
2 µS
1.6 µS
2. SIO2 port:
• To support DDC2B/2B+/2Bi/2AB, use P4.4 (SCL) for serial clock and P4.5 (SDA) for serial data.
DDC1 Port
The DDC1 is a serial output port that supports DDC1 communication. To enable the DDC1 port,
ENDDC1 (bit 3 of CTRL1) should be set to '1'. Once previous eight data bits in the shift register and
one null bit (the 9th bit) are shifted out to the SDA sequentially on each rising edge of the VIN signal,
the DDC1 control circuit loads the next data byte from the latch buffer (the DDC1 register) to the shift
register and generates a DDC1INT signal to the CPU. In the interrupt service routine, the S/W should
fetch the next byte of EDID data and write it to the DDC1 register. If ENDDC1 is cleared, the shift
register is stopped, and the SDA output is kept high. The bit DDC1B9 (bit 4 of CTRL2) decides the 9th
bit in a DDC transmission. If DDC1B9 is set, the 9th bit will be '1', otherwise '0'.
- 16 -