English
Language : 

DG611A_11 Datasheet, PDF (6/15 Pages) Vishay Siliconix – 1 pC Charge Injection, 100 pA Leakage, Quad SPST Switches
DG611A, DG612A, DG613A
Vishay Siliconix
SPECIFICATIONS FOR UNIPOLAR SUPPLIES (V + = + 3 V, V - = 0 V)
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
V+ = + 3 V, V- = 0 V
VIN = 1.4 V, 0.6 Va
Temp.b
Typ.c
- 40 °C to 125 °C - 40 °C to 85 °C
Min.d Max.d Min.d Max.d
Analog Signal Rangee
VANALOG
Full
0
3
0
3
On-Resistance
RON
IS = 1 mA, VD = + 1.5 V
Room 195
Full
235
235
300
280
Switch Off
Leakage Current
IS(off)
ID(off)
V + = 3.3 V, V- = 0 V
VD = 3 V/0.3 V
VS = 0.3 V/3 V
Room
Full
Room
Full
± 0.02
± 0.02
- 0.1
-2
- 0.1
-2
0.1 - 0.1 0.1
2 - 0.25 0.25
0.1 - 0.1 0.1
2 - 0.25 0.25
Switch On
Leakage Current
ID(on)
V + = 3.3 V, V- = 0 V
VD = VS = 0.3 V/3 V
Room ± 0.02
Full
- 0.1
-6
0.1 - 0.1 0.1
6 - 0.25 0.25
Digital Control
Input Current, VIN Low
IIL
VIN Under Test = 0.6 V
Full 0.005 - 0.1 0.1 - 0.1 0.1
Input Current, VIN High
Input Capacitancee
IIH
VIN Under Test = 1.4 V
Full 0.005 - 0.1 0.1 - 0.1 0.1
CIN
f = 1 MHz
Room
2
Dynamic Characteristics
Turn-On Time
Turn-Off Time
tON
Room
87
RL = 300 , CL = 35 pF
Full
tOFF
VS = 2 V, see figure 1
Room
33
Full
125
125
180
170
55
55
65
60
Break-Before-Make
Time Delay
tBBM
DG613 only, VS = 2 V
Room
60
RL = 300 , CL = 35 pF
Full
10
10
Charge Injectione
Q
Vg = 0 V, Rg = 0 , CL = 1 nF Room
2.3
Off Isolatione
Channel-to-Channel
Crosstalke
OIRR
XTALK
RL = 50 , CL = 5 pF
f = 10 MHz
Room - 60
Room - 90
3 dB Bandwidthe
BW
RL = 50 , CL = 5 pF
Room 550
Source Off Capacitancee
Drain Off Capacitancee
CS(off)
CD(off)
f = 1 MHz; VS = 0 V
Room
5
Room
6
Drain On Capacitancee
CD(on)
f = 1 MHz; VS = VD = 0 V Room
9
Power Supplies
Power Supply Current
I+
Room 0.001
0.1
0.1
Full
1
1
Negative Supply Current
I-
VIN = 0 V or 3 V
Room - 0.001 - 0.1
Full
-1
- 0.1
-1
Ground Current
IGND
Room - 0.001 - 0.1
Full
-1
- 0.1
-1
Unit
V

nA
µA
pF
ns
pC
dB
MHz
pF
µA
Notes:
a. VIN = input voltage to perform proper function.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
Document Number: 69904
6
S11-1066-Rev. C, 30-May-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000