English
Language : 

DG408L_08 Datasheet, PDF (6/12 Pages) Vishay Siliconix – Precision 8-Ch/Dual 4-Ch Low Voltage Analog Multiplexers
DG408L/409L
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 3 V)
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 3 V, ± 10 %, V- = 0 V
VEN = 0.4 V or 2.0 Vf
A Suffix
D Suffix
- 55 to 125 °C - 40 to 85 °C
Tempb Typd Minc Maxc Minc Maxc Unit
Analog Signal Rangee
VANALOG
Full
0
3
0
3
V
Drain-Source On-Resistance rDS(on)
V+ = 2.7 V, VD = 0.5 or 2.2 V,
IS = 5 mA
Room 60
Full
80
105
80
100
Ω
Switch Off Leakage Currenta
IS(off)
ID(off)
V+ = 3.3 V, VS = 2 or 1 V, VD = 1 or 2 V
Room
Full
Room
Full
-1
1
-1
1
- 15 15 - 10 10
-1
- 15
1
15
-1
- 10
1
10
nA
Channel On Leakage
Currenta
ID(on)
V+ = 3.3 V, VD = VS = 1 or 2 V
Sequence Each Switch On
Room
Full
-1
1
-1
1
- 15 15 - 10 10
Digital Control
Logic High Input Voltage
Logic Low Input Voltage
Input Currenta
Dynamic Characteristics
VINH
VINL
IIN
Full
Full
VAX = VEN = 2.4 V or 0.4 V
Full
2
2
V
0.4
0.4
- 1.5 1.5 - 1
1
µA
Transition Time
tTRANS
VS1 = 1.5 V, VS8 = 0 V, (DG408L)
VS1b = 1.5 V, VS4b = 0 V, (DG409L)
Room
Full
75
See Figure 2
150
150
175
175
Break-Before-Make Time
Enable Turn-On Time
Enable Turn-Off Time
tOPEN
tON(EN)
tOFF(EN)
VS(all) = VDA = 1.5 V,
See Figure 4
Room 32
Full
Room 70
VAX = 0 V, VS1 = 1.5 V (DG408L)
Full
VAX = 0 V, VS1b = 1.5 V (DG409L)
See Figure 3
Room
Full
55
1
1
ns
95
95
115
105
100
100
115
105
Charge Injectione
Q
CL = 1 nF, RGEN = 0 Ω, VGEN = 0 V Room 0.4
5
5 pC
Off Isolatione, h
Crosstalke
OIRR
XTALK
RL = 1 kΩ, f = 100 kHz
Room - 70
Room - 79
dB
Source Off Capacitancee
CS(off)
f = 1 MHz, VS = 0 V, VEN = 0 V
Room 8
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 0 V
Room 19
pF
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 2 V
(DG409L only)
Room 33
Notes:
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. ΔrDS(on) = rDS(on) Max - rDS(on) Min.
h. Worst case isolation occurs on Channel 4 do to proximity to the drain pin.
i. rDS(on) flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
6
Document Number: 71342
S-71241–Rev. E, 25-Jun-07