English
Language : 

DG408L_08 Datasheet, PDF (5/12 Pages) Vishay Siliconix – Precision 8-Ch/Dual 4-Ch Low Voltage Analog Multiplexers
DG408L/409L
Vishay Siliconix
SPECIFICATIONS (SINGLE SUPPLY 5 V)
Parameter
Analog Switch
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 5 V, ± 10 %, V- = 0 V
VEN = 0.6 V or 2.4 Vf
A Suffix
D Suffix
- 55 to 125 °C - 40 to 85 °C
Tempb Typd Minc Maxc Minc Maxc Unit
Analog Signal Rangee
VANALOG
Full
0
5
0
5
V
Drain-Source On-Resistance rDS(on)
V+ = 4.5 V, VD or VS = 1 V or 3.5 V, Room 35
ID = 5 mA
Full
49
62
40
62
rDS(on) Matching Between
Channelsg
ΔrDS
V+ = 4.5 V, VD = 1 V or 3.5 V,
Room 1.5
3
On-Resistance Flatnessi
rFLAT(on)
IS = 5 mA
Room
4
Ω
3
4
Switch Off Leakage Currenta
IS(off)
ID(off)
V+ = 5.5 V, VS = 1 V or 4 V
VD = 4 V or 1 V
Room
Full
Room
Full
-1
1
-1
1
- 15 15 - 10 10
-1
1
-1
1
- 15 15 - 10 10 nA
Channel On Leakage
Currenta
ID(on)
V+ = 5.5 V, VD = VS = 1 V or 4 V
Sequence Each Switch On
Room
Full
-1
1
-1
1
- 15 15 - 10 10
Digital Control
Logic High Input Voltage
Logic Low Input Voltage
Input Currenta
Dynamic Characteristics
VINH
VINL
IIN
Full
V+ = 5 V
Full
VAX = VEN = 2.4 V or 0.6 V
Full
2.4
2.4
V
0.6
0.6
- 1.5 1.5 - 1
1
µA
Transition Timee
tTRANS
VS1 = 3.5 V, VS8 = 0 V, (DG408L)
VS1b = 3.5 V, VS4b = 0 V, (DG409L)
See Figure 2
Room 44
Full
125
125
138
135
Break-Before-Make Timee
tOPEN
VS(all) = VDA = 3.5 V,
See Figure 4
Room 17
1
Full
1
ns
Enable Turn-On Timee
tON(EN)
VAX = 0 V, VS1 = 3.5 V (DG408L)
Room 43
Full
60
70
60
65
Enable Turn-Off Timee
tOFF(EN)
VAX = 0 V, VS1b = 3.5 V (DG409L)
See Figure 3
Room 26
Full
45
60
45
50
Charge Injectione
Q
CL = 1 nF, RGEN = 0 Ω, VGEN = 0 Ω Room 1
5
5 pC
Off Isolatione, h
Crosstalke
OIRR
XTALK
f = 100 kHz, RL = 1 kΩ
Room - 70
Room - 80
dB
Source Off Capacitancee
CS(off)
f = 1 MHz, VS = 0 V, VEN = 0 V
Room 8
Drain Off Capacitancee
CD(off)
f = 1 MHz, VD = 0 V, VEN = 0 V
Room 21
pF
Drain On Capacitancee
CD(on)
f = 1 MHz, VD = 0 V, VEN = 2.4 V
(DG409L only)
Room 32
Notes:
a. Leakage parameters are guaranteed by worst case test condition and not subject to production test.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
d. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
g. ΔrDS(on) = rDS(on) Max - rDS(on) Min.
h. Worst case isolation occurs on Channel 4 do to proximity to the drain pin.
i. rDS(on) flatness is measured as the difference between the minimum and maximum measured values across a defined Analog signal.
Document Number: 71342
S-71241–Rev. E, 25-Jun-07
www.vishay.com
5