Vishay Semiconductors
SAFETY AND INSULATION RATINGS
PARAMETER
SYMBOL
MIN.
TYP.
MAX.
UNIT
Climatic classification (according to IEC 68 part 1)
Pollution degree (DIN VDE 0109)
55/100/21
2
Comparative tracking index
CTI
175
Peak transient overvoltage
Peak working insulation voltage
Partial discharge test voltage (method a, Vpd = VIORM x 1.875)
Isolation resistance at Tamb = 100 °C, VDC = 500 V
Isolation resistance at Tamb = 25 °C, VDC = 500 V
Safety rating - power
Safety rating - input current
Safety rating - temperature
Clearance distance (Standard DIP-6)
VIOTM
VIORM
Vpd
RIO
RIO
PSO
ISI
TSI
1011
1012
7
8000
890
1669
265
130
150
Vpeak
Vpeak
Vpeak
Ω
Ω
mW
mA
°C
mm
Creepage distance (Standard DIP-6)
Clearance distance (400 mil DIP-6)
7
mm
8
mm
Creepage distance (400 mil DIP-6)
8
mm
Note
• According to DIN EN60747-5-5 (see figure 4). This optocoupler is suitable for safe electrical isolation only within the safety ratings.
Compliance with the safety ratings shall be ensured by means of suitable protective circuits.
300
Psi (mW)
250
200
150
Isi (mA)
100
50
0
0 25 50 75 100 125 150
Tamb - Ambient Temperature (°C)
Fig. 4 - Safety Parameter Derating Diagram
VIOTM
Vpd
VIOWM
VIORM
t1, t2 = 1 s to 10 s
t3, t4 = 1 s
ttest = 10 s
tstres = 12 s
0
13930
t1
tTr = 60 s
t3 ttest t4
t2 t stres
t
Fig. 5 - Test Pulse Diagram for Sample Test according to
DIN EN60747-5-5/DIN EN60747-; IEC 60747