English
Language : 

SI4943CDY Datasheet, PDF (2/9 Pages) Vishay Siliconix – Dual P-Channel 20-V (D-S) MOSFET
Si4943CDY
Vishay Siliconix
New Product
SPECIFICATIONS TJ = 25 °C, unless otherwise noted
Parameter
Symbol
Test Conditions
Static
Drain-Source Breakdown Voltage
VDS Temperature Coefficient
VGS(th) Temperature Coefficient
Gate Threshold Voltage
Gate-Body Leakage
Zero Gate Voltage Drain Current
On-State Drain Currentb
Drain-Source On-State Resistanceb
Forward Transconductanceb
Dynamica
VDS
ΔVDS/TJ
ΔVGS(th)/TJ
VGS(th)
IGSS
IDSS
ID(on)
RDS(on)
gfs
VGS = 0 V, ID = - 250 µA
ID = - 250 µA
VDS = VGS, ID = - 250 µA
VDS = 0 V, VGS = ± 20 V
VDS = - 20 V, VGS = 0 V
VDS = - 20 V, VGS = 0 V, TJ = 55 °C
VDS = 5 V, VGS = - 10 V
VGS = - 10 V, ID = - 8.3 A
VGS = - 4.5 V, ID = - 6.4 A
VDS = - 10 V, ID = - 8.3 A
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge
Ciss
Coss
Crss
Qg
VDS = - 10 V, VGS = 0 V, f = 1 MHz
VDS = - 10 V, VGS = - 10 V, ID = - 8.3 A
Gate-Source Charge
Qgs
VDS = - 10 V, VGS = - 4.5 V, ID = - 8.3 A
Gate-Drain Charge
Qgd
Gate Resistance
Rg
f = 1 MHz
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
tr
td(off)
VDD = - 10 V, RL = 1.5 Ω
ID ≅ - 6.7 A, VGEN = - 10 V, Rg = 1 Ω
Fall Time
tf
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
tr
td(off)
VDD = - 10 V, RL = 1.5 Ω
ID ≅ - 6.7 A, VGEN = - 4.5 V, Rg = 1 Ω
Fall Time
tf
Drain-Source Body Diode Characteristics
Continuous Source-Drain Diode
Current
IS
TC = 25 °C
Pulse Diode Forward Currenta
ISM
Body Diode Voltage
VSD
IS = - 6.7 A
Body Diode Reverse Recovery Time
trr
Body Diode Reverse Recovery Charge
Qrr
Reverse Recovery Fall Time
ta
IF = - 6.7 A, dI/dt = 100 A/µs, TJ = 25 °C
Reverse Recovery Rise Time
tb
Notes:
a. Guaranteed by design, not subject to production testing.
b. Pulse test; pulse width ≤ 300 µs, duty cycle ≤ 2 %.
Min.
- 20
-1
- 30
0.5
Typ.a
- 21
5.4
0.0160
0.0275
19
1945
460
385
41
20
7
9
2.5
13
11
35
10
50
71
29
15
- 0.77
30
17
13
17
Max.
-3
- 100
-1
- 10
0.0192
0.0330
62
30
5
20
17
53
15
75
107
44
23
- 2.5
- 30
- 1.2
45
26
Unit
V
mV/°C
V
nA
µA
A
Ω
S
pF
nC
Ω
ns
A
V
ns
nC
ns
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
www.vishay.com
2
Document Number: 69985
S09-0704-Rev. B, 27-Apr-09