TCET1110_07 Datasheet, PDF (1/11 Pages) Vishay Siliconix – Optocoupler, Phototransistor Output, High Temperature, 110 °C Rated | |||
|
TCET1110/TCET1110G
Vishay Semiconductors
Optocoupler, Phototransistor Output,
High Temperature, 110 °C Rated
CE
17918_1
1
C
AC
DVE
DESCRIPTION
The TCET1110/ TCET1110G consists of a phototransistor
optically coupled to a gallium arsenide infrared-emitting
diode in a 4-pin plastic dual inline package.
The elements are mounted on one leadframe, providing a
fixed distance between input and output for highest safety
requirements.
VDE STANDARDS
These couplers perform safety functions according to the
following equipment standards:
⢠DIN EN 60747-5-2 (VDE 0884)/DIN EN 60747-5-5
pending
Optocoupler for electrical safety requirements
⢠IEC 60950
Office machines (applied for reinforced isolation for mains
voltage ⤠400 VRMS)
⢠VDE 0804
Telecommunication apparatus and data processing
⢠IEC 60065
Safety for mains-operated electronic and related
household apparatus
FEATURES
⢠CTR offered in 9 groups
⢠Isolation materials according to UL94-VO
⢠Pollution degree 2
(DIN/VDE 0110/resp. IEC 60664)
⢠Climatic classification 55/100/21
(IEC 60068 part 1)
⢠Special construction: therefore, extra low coupling capacity
of typical 0.2 pF, high Common Mode Rejection
⢠Low temperature coefficient of CTR
⢠Temperature range - 40 to + 110 °C
⢠Rated impulse voltage (transient overvoltage)
VIOTM = 8 kVpeak
⢠Isolation test voltage (partial discharge test voltage)
Vpd = 1.6 kV
⢠Rated isolation voltage (RMS includes DC)
VIOWM = 600 VRMS
⢠Rated recurring peak voltage (repetitive)
VIORM = 848 peak
⢠Creepage current resistance according to VDE 0303/
IEC 60112 Comparative Tracking Index: CTI ⥠175
⢠Thickness through insulation ⥠0.75 mm
⢠External creepage distance > 8 mm
⢠Lead (Pb)-free component
⢠Component in accordance to RoHS 2002/95/EC and
WEEE 2002/96/EC
AGENCY APPROVALS
⢠UL1577, file no. E76222 system code U, double protection
⢠BSI: EN 60065:2002, EN 60950:2000
certificate no. 7081 and 7402
⢠DIN EN 60747-5-2 (VDE 0884)
DIN EN 60747-5-5 pending
⢠FIMKO
APPLICATIONS
⢠Switch-mode power supplies
⢠Line receiver
⢠Computer peripheral interface
⢠Microprocessor system interface
⢠Circuits for safe protective separation against electrical
shock according to safety class II (reinforced isolation):
- for appl. class I - IV at mains voltage ⤠300 V
- for appl. class I - III at mains voltage ⤠600 V
according to DIN EN 60747-5-2 (VDE 0884)/
DIN EN 60747-5-5 pending.
Document Number: 83546
Rev. 1.8, 21-Nov-07
For technical questions, contact: optocoupler.answers@vishay.com
www.vishay.com
1
|
▷ |