English
Language : 

V23990-K229-A41-PM Datasheet, PDF (7/18 Pages) Vincotech – Trench Fieldstop IGBT4 technology
V23990-K229-A41-PM
T1,T2,T3,T4,T5,T6,T7 / D1,D2,D3,D4,D5,D6,D7
Figure 9
Typical switching times as a
function of collector current
t = f(IC)
1
tf
0,1
tdon
T1,T2,T3,T4,T5,T6,T7 IGBT
tdoff
Figure 10
Typical switching times as a
function of gate resistor
t = f(RG)
1
tdoff
0,1
tr
T1,T2,T3,T4,T5,T6,T7 IGBT
tdon
tf
tr
0,01
0,01
0,001
0
0,001
10
20
30
40
I C (A) 50
0
30
60
90
120 R G ( Ω ) 150
With an inductive load at
Tj =
150
°C
VCE =
600
V
VGE =
±15
V
Rgon =
32
Ω
Rgoff =
32
Ω
With an inductive load at
Tj =
150
°C
VCE =
600
V
VGE =
±15
V
IC =
25
A
Figure 11
Typical reverse recovery time as a
function of collector current
trr = f(IC)
1
D1,D2,D3,D4,D5,D6,D7 FWD
0,8
trr
Tj = Tjmax -25°C
0,6
trr
0,4
Tj = 25°C
0,2
Figure 12
Typical reverse recovery time as a
function of IGBT turn on gate resistor
trr = f(Rgon)
1
D1,D2,D3,D4,D5,D6,D7 FWD
trr
0,8
Tj = Tjmax -25°C
0,6
trr
Tj = 25°C
0,4
0,2
0
0
0
10
20
30
40
I C (A) 50
0
30
60
90
120 R g on ( Ω ) 150
At
Tj =
VCE =
VGE =
Rgon =
25/150 °C
600
V
±15
V
32
Ω
At
Tj =
VR =
IF =
VGE =
25/150 °C
600
V
25
A
±15
V
copyright Vincotech
7
Revision: 4.1